    Extension roof issue

    I’ve done some testing with a hose and the drip edges are working, however I think the front edge over hang is too shallow hence why it’s dripping on the wall. To confirm this i’ve bonded a L shaped strip to the leading edge of the copeing to divert the run off away. I think as others have...
  2. S

    Extension roof issue

    Hi All Looking for some advice. We had a single story extension designed and built 8 years ago. Since it’s construction we have had issues with water running off the parapet walls down the face of the wall. This happens on both sides. The initial builder did some remedy work initially but...
  3. S

    Odd central heating issue

    So it’s all fixed. The hidden zone valve had a faulty motor, so once i changed that and learned from your helpful advice that the honeywell valve doesn’t move like the drayton it’s all back and running. Thanks for all your help
  4. S

    Odd central heating issue

    Ah - i thought they behaved like the Drayton ones. what you said is correct. Not energised it has a bit of resistance, power no resistance. I run it and see if it works. Just assumed it wasn’t. Steve
  5. S

    Odd central heating issue

    Ok so it seems as if the installers just piggy backed the hidden valve and the new valve together. The hidden valve didn't move when called for heat. So I went out and got a replacement motor and swapped it over. I can see the motor and springs now turning, however the switch bar (auto - manual)...
  6. S

    Odd central heating issue

    Thanks both for your reply. As far as i’m aware the downstairs two are connected to upstairs. This historically evident as when the upstairs is on the downstairs two come on. I’m having difficulty tracking a cold spot as the pipes leading from the downstairs rad that then goes up to the airing...
  7. S

    Odd central heating issue

    Yes. The downstairs circuit is hot and the two rads connected to the upstairs are hot. So the valves are actuating, otherwise I wouldn't have the two rads downstairs working. If they didn't then I would have thought it was a zone valve. Ive even switched the zone valve that does the hot water...
  8. S

    Odd central heating issue

    Do you mean zone valves? if so yes one on the upstairs circuit the other downstairs.
  9. S

    Odd central heating issue

    Ive checked the flow of pipes from the garage to the airing cupboard and all solid copper pipes as these go straight up into the airing cupboard
  10. S

    Odd central heating issue

    Hi All Hope you might help at all. In short we have no heating upstairs, all rads are stone cold from the feed and return pipes of each rad up to the top of the rads - not even tepid. We have two heating circuits. one which is underfloor heating to the entire downstairs of the house. The other...
  11. S

    Powermax 155

    thanks for the reply. Its strange, the panel works fine, setting times, changing modes. It just wont work when you set it to auto. One thing I did notice was that when I first noticed a problem, I looked at the programmer panel and the clock said 11.30pm (it was 6:35am) Somehow its changed...
  12. S

    Powermax 155

    Hi, im wondering if anyone could help with my problem. I have the above boiler. its about 3 years old and has worked fine for hot water and CH. Today the programed times didnt fire the boiler and therefore there isnt any HW. If I pressed advance it would normally skip to the next on time...