Search results

  1. G

    SIEMENS WIRELESS THERMOSTAT

    had a few probs with wireless stuff ring maufac cos i had same probs but it happened every week with a worcester one and worcester say that theirs will only go though 1 internal wall and wont go though a outside wall which seems a bit stupid
  2. G

    I think I have an air lock

    sounds like the ball valve is stuck where did u turn the water off to do the work? if you turned it off at the main tap then its deff your ball valve about £5 really easy to do the components can get stuck so it only lets a trickle out
  3. G

    Noisy ( whining ) micro bore central heating

    you said that all the rads have trv's (thermostatic rad valve) fitted if this is true check that a bypass is fitted normal systems have 1 rad with no trv on due to the fact that when the trv gets up to temp it shuts the rad off if all the rads shut off the pump is still going with no where to...
  4. G

    baxi wm 60/40 rs solo

    i always change the overheat stat on these when i have had probs with pilot going out intermit seem to be a bit dodgy on these for the sake of a tenner
  5. G

    Stop cocks and gate valves

    great fun when you shut a gate valve on a cold feed from a tank and it doesnt open back up again
  6. G

    best make of condensing combi for 3 bed semi

    get a worcester!!!!!!!!!!
  7. G

    hardly any cold water coming out of tap

    is it just the bathroom taps? or is it just the bath taps or all the taps in your house?
  8. G

    Has the bath got an overflow

    yeah every bath has got a overflow looks like they are trying to pull a fast 1
  9. G

    Potterton Suprima 30

    real problem bolier 3 really common faults on these = gas valve,pcb and spark electrodes red light not flashing = no fault (its in standby mode with no demand or its in the delay mode normaly about 1-2 mins) red light flashing = fault green light flashing = lighting green light = flame...
Back