  1. T

    MIV and MAM

    Hi can any one help me with this I have Just started my gas course only a week In so early days yet. I'm trying to wright all the abbreviated words down So they will stick in my head but I'm having a problem Finding what MIV and MAM stand for can any one Tell me. Ed
  2. T

    Single story extension

    Thanks for the serious answers. If more information was needed to give an answer that was all any body had to say. If no answer could be given with out more information that was all any body had to say. Throwing Ducks around What's all that about. Trying to dig some footings to save...
  3. T

    Single story extension

    ? Simple question I don't really understand why the funny coments. What's the regs on depth (if any) for a single story.
  4. T

    Single story extension

    Hi there can any one help me I'm building a single story extension And I need to know how wide and deep to dig the footings. Ed [/b]
  5. T

    New soil pipe to main drain

    Hi there I want to put a new bathroom in my house and need to lay a new underground soil pipe to the manhole at the end of my garden is there any advice you can give me. Eddie
  6. T

    Baxi combi 80 echo

    Thanks Geegas You were spot on changed the micro switch On the front and everything working fine. Cheers Eddie.
  7. T

    Baxi combi 80 echo

    Ok thanks for that ill try it. Eddie
  8. T

    Baxi combi 80 echo

    Hi there yeah the top pin comes up And the boiler fires up. Eddie
  9. T

    Baxi combi 80 echo

    Hi there as soon as the boiler is switched on to eather hot water Or heating and hot water the pin Comes out and makes a contact with the Switch that makes the heating fire up. Eddie
  10. T

    Baxi combi 80 echo

    Hi there can anyone help with this problem. The radiations are allways on even when I select just water on the selector Switch on the front of the boiler. The rads cool down when I run the hot water and the diverter seems To be working fine the pins seem to be moving freely. Eddie
  11. T

    Baxi combi 80 echo

    Hi there just checking because in the Manual it says there are two side to this Diverter. Eddie.
  12. T

    Baxi combi 80 echo

    Baxi combi 80echo When the hot water is run the rads are getting hot Is this the hot water valve or the central valve As this diverter has two separate valves. thanks Eddie
  13. T

    Renualt kangoo

    Hi there I've got a 2006 renualt kangoo van that seems to be riding Low on the back does any body know How to solve this problem. There's no springs on the rear only shocks. Eddie.
  14. T

    Pump for electric shower

    Any idea if I can fit a 1bar pump to a Mira sport electric shower Problem is a farm house is fed by a natural spring and the water pressure is not good as its tank fed. Any other ideas would be great Eddie.
  15. T

    worcester 9.24

    hi there i have a Worcester 9.24 quite an old boiler when the heating is on or hot water drawn the is a banging noise after about 30 secs or so then the boiler locks out do you think its the pump i carnet seem to hear or feel the pump running at all. Eddie
  16. T

    thermocouple

    Can you tell me if all thermocouples Are the same or do I have to get the Right one for my boiler Eddie
  17. T

    Rads getting hot Shen heating off

    Sorry forgot to say it's a combi boiler
  18. T

    Rads getting hot Shen heating off

    Hi there my daughter has said that some of the radiators are getting hot but the heating has been turned of would this be the diverter valve And ideas Eddie
  19. T

    Saunier Duval F30 E

    Hi there wonder if you had any ideas My daughters boiler Saunier Duval F30 E Seems to be playing up. When you run the hot water you have to slow The flow right down to get the water hot Especially for the bath any ideas Eddie.
  20. T

    boiler regs

    hi there what do the regs say about instaling a boiler in a bathroom.
Back