Search results

  1. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    I went down to Screwfix and picked up a ZA5 valve actuator for £42,99. Fitted it in 10 minutes when I got home and all is well. Thanks to all of the contributors to this thread. CVB
  2. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    Thanks very much for your time and effort helping me sort out this problem. I'll post when I've got it working again. CVB
  3. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    I took the actuator apart and found three things that did not look quite right - a small piece of grey plastic broken off the stop post a small piece of black plastic broken off the top of the post that holds the quadrant and delivers the movement to the valve spindle a couple of teeth...
  4. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    Yes, I have a multimeter and have used it for connectivity, voltage measurements, etc. plus I have a neighbour who could help out if it gets complicated. CVB
  5. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    I did the first check as suggested and the ch valve tried to open but clicked closed immediately it reached the fully open position. Neither the pump not the boiler came on. Note that I have an oil-fired boiler that has its own temperature controller built into it so that may have prevented it...
  6. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    See new picture below There is a white wire (A) but it is not connected but left, as you see, taped up. The other white 'cable' you see is not a cable because it has no conductor in it - it's like a flexible plastic rod (to make up six 'conductors' in the black sheath for better packing of...
  7. Untitled

    Untitled

  8. central Heating Junction Box

    central Heating Junction Box

  9. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    Here are some images I took today. The valve giving the problem is at the back. CVB
  10. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    Thanks - found the catch on the side. The way the valve is situated, I could not see the release catch. I removed the actuator and found that the pipe part of the valve seemed to be in good order with little effort needed to rotate it through about 60 degrees (guess) I have two motorised...
  11. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    So how does the box come off the spindle? My whole system is based on mains pressure NOT gravity.
  12. C

    Drayton Zone Valve Actuator ZA6 - Loud Banging Noise

    When the heating came on this after (timer - 2 periods morning and evening) there was a loud banging noise transmitted through the central heating pipes every 20 seconds or so. When I went to the airing cupboard, I found the noise was coming from the above valve. The lever on the side moved from...
  13. C

    Boulter 50-70 Economy Oil Boiler + Riello G5 Economy 50/70

    Well, it's been running, without missing a beat, for over a month so thanks to all the contributors for saving me from wasting yet more money with so-called experts. CVB
  14. C

    Boulter 50-70 Economy Oil Boiler + Riello G5 Economy 50/70

    A quick update - the condenser arrived last Friday afternoon and I fitted it as soon as it arrived - quite an easy operation. It has been running now for two days and has not missed a beat so I'm keeping my fingers crossed that I've solved the problem with your help. If it all goes t*ts up...
  15. C

    Boulter 50-70 Economy Oil Boiler + Riello G5 Economy 50/70

    I spoke today to a nice guy at Riello called Graham who works in their technical department. He came to the same conclusion as you, Burnerman, and suggested I replace the capacitor. I was given the part number and ordered one from Vitalise Trading on Ebay for £10. I'll let you know the outcome...
  16. C

    Boulter 50-70 Economy Oil Boiler + Riello G5 Economy 50/70

    Thanks for that, Burnerman. Would a tired capacitor produce the symptoms - intermittent failure to start - and are they standard parts or particular to each motor? Is it easy to fit - a couple of screws/bolts on the outside of the burner assembly - or do you have to take the motor off to get to...
  17. C

    Boulter 50-70 Economy Oil Boiler + Riello G5 Economy 50/70

    I have one of the above boiler/burner combinations to heat my bungalow and it was probably installed in 1999. It has been playing up for a couple of years by not starting up when it should. When it refuses to start automatically, it can be started by manually pressing the "Reset" but...
  18. C

    Hinges for "top hung" aluminium double glazing

    I'm attempting to repair a couple of broken hinges on aluminium double glazing in my mother's house. The units are about 20 years old. If these windows were traditional casements they would be top-hung but being double glazing they have a 200mm friction hinge on each side. Simple, I thought -...
Back
Top