  1. M

    Replacing a standard boiler with a combi - a good idea?

    pressure would drop on outlets and if you was having a shower and somebody else opened a hot water tap, anywhere else in the house, the shower water could get cold. For your house, stay away from a combi.
  2. M

    Potterton Puma 80e

    changed the diverter valve and still same problem. Called in a corgi engineer and bingo the fault is as fella kuti thought. Main burner not going onto high fire in CH mode after 90 seconds, as the manual says. But wait, the corgi engineer is lost. he hasn't got a clue how to fix it...
  3. M

    Potterton Puma 80e

    Hi all, Pump checks out ok. I'll change the wax capsule next. Good point from fela kuti, When constant demand for CH is called for the burner lights but stays on one pressure setting if in the meantime DHW is called for the burner goes into high fire. As soon the demand for DHW is removed the...
  4. M

    Potterton Puma 80e

    Thanks ChrisR, Got hold of the manual. Will check both pump and diverter value. let you know how I get on.
  5. M

    More flow needed to get hot water from combi boiler

    Theres a HRPC Shop in your area. They will carry all the parts.
  6. M

    Potterton Puma 80e

    How can I check if the pump is faulty, i've checked and there is voltage ok to it. Is there anyway I can check it before replacing it with a new one.
  7. M

    Potterton Puma 80e

    I think i'm stuck with the worst boiler on the planet! The tap water does actually fluctuate in temperature, sometimes very very hot.
  8. M

    Potterton Puma 80e

    guys I haven't got a manual for the boiler, where abouts is the diverter valve located.
  9. M

    Potterton Puma 80e

    It's true, the boiler stays on and doesn't cut out at all, i've watched it for 20 minutes. I agree the heat has to go somewhere, its a combi boiler other than a hot water tap where else can the heat go. As i said there are bursts of very hot water through the flow pipe for a few seconds.
  10. M

    Potterton Puma 80e

    Hi all, After running the central heating for an hour the rads only get slightly warm. I have flushed the system recently. The Flow pipe from the Puma 80e only gets slightly warm as well. It does however have bursts of getting very hot for a few seconds. The boiler is constantly on full fire...
  11. M

    Cold New Radiator

    Thanks for your help Eliteheat, I tried what you suggested but no improvement. Maybe new Rad is faulty or sludge stuck in it. Some other rads are now cold as well.
  12. M

    Cold New Radiator

    I've replaced a single Rad with a double rad upstairs. The top of the radiator is hot but the bottom is cold. The inlet pipe is very hot but the outlet pipe is cold. Any suggestions