    Help installing DT92E Wireless Stat

    Thanks D-Hailsham, I didn't see you post, must have ben typing mine at the same time..... On a seperate note, I am looking at replacing the Danfoss FP715 for nothing other than asthetic reasons, it's looking a bit shabby and I would prefer a white programmer to match the other kit. Any...
  2. C

    Help installing DT92E Wireless Stat

    OK - panic over. When taking a look at the boiler PCB, i noticed that the programmer (on the wall beneath the boiler) was at a slight angle, so being the anal git that I am, I straightened it a bit , and hey presto, the boiler kicked in. Have played around with it all all appears to be fine...
  3. C

    Help installing DT92E Wireless Stat

    Would this fuse just control the CH or Water as well, because a call for hot water is still working OK. Regardless, I couldn't see the fuse on the boiler PCB, but in fairness, unless it looked like a conventional fuse, I may well have missed it. There is a 2amp glass fuse in the honeywell...
  4. C

    Help installing DT92E Wireless Stat

    OK, I spoke too soon! Have wired this up as you suggested and all appears to be OK, the call to the boiler is being made, but the boiler does not respond. That could be because I made a mistake when connecting the wire in to the honeywell wiring centre. I mistakingly put the wire form B to...
  5. C

    Help installing DT92E Wireless Stat

    D_Hailsham, I can't thank you enough - you are fantastic!! :lol: All up and running as per you last post. I took the option of ditching the old cable and runing 2 new twin core cables, which saved me having to use the Earth as Live, and made for a simpler job of wiring up the receiver...
  6. C

    Help installing DT92E Wireless Stat

    Thanks D_Hailsham! Before i get the screwdriver back out, can you check out the picture which should help me understand things..... At the moment on the room stat wiring block of the honywell wiring centre, T1 is a yellow wire, E is the earth, T2 is empty, T3 is a red wire. There is a blue...
  7. Homeywell Wiring Centre

    Homeywell Wiring Centre

  8. CM

    CM

  9. C

    Help installing DT92E Wireless Stat

    Hi all, I am trying to install a Honeywell DT92E to my exisitng system. At the moment I have a wired stat (Servowarm) which has a 3 core and earth cable connecting to it from a Honeywell Wiring Centre. Only two of the cores and the earth are being used at both ends. (Yellow, Red and Earth)...
  10. C

    Potterton Puma 80e CH problem

    Hi Guys, I did try the pump, and I thought that it looked OK. Bit the bullet and got BG to come round (the same day that I called them). They diagnosed the pump straight away, and 24 hours later we are back up and running. Thanks to all that offered a solution to this. If only I knew...
  11. C

    Potterton Puma 80e CH problem

    Thanks for the quick responses guys.... Don't feel confident enough to fiddle with this.... I took the black cap off the front of the pump and undone the nut and pulled out about 1cm, but this was red hot, so didn't venture any further. Have just noticed that the pressure has now...
  12. C

    Potterton Puma 80e CH problem

    Good question. How do I tell if the pump is running OK? I just touched it (HW tap running for a few mins whilst washing up) and the metal front on the pump was very warm to touch!! Is the diverter a easy/quick job? Thanks, Chris
  13. C

    Potterton Puma 80e CH problem

    Hi all, Just about to move house and the boiler has started playing up!! Potterton Puma 80e. HW seems to work fine but boiler is more noisy than normal. CH, when turned on the boiler ignites OK, then makes noises as though air is trapped somewhere. After 10 seconds or so water, then...
  14. C

    Potterton Puma 80e CH on even though switch is off

    Fantastic - this is exactly what it was. Part ordered was a DHW thermostat, but instead or replacing this, they replaced the frost stat by mistake!! Lucky they left me the old parts - put the old frost stat back in all is working fine!! Thank you so much for your help!!
  15. C

    Potterton Puma 80e CH on even though switch is off

    Hi all, I have a potterton Puma 80e that is about 8yrs old. When the boiler is turned on we got DHW no problem at all, but we also get CH, even though the CH switch is off. Had never had this problem before on the boiler. So, what led up to this situation...... Water from a...
  16. C

    Independant report required following bodged insurance claim

    Hi all, Following an insurance claim last year we had our kitchen completely removed and the concrete floor taken up and replaced (The screed had blown following a water leak) The new concrete floor (well part of it) has now also blown. I suspect that this part of the floor was never...