Search results

  1. S

    damp problems

    Hi Thanks for all the replies I've been thinking about this occurrence since reading these and have concluded that I will drill a 11/2" hole below the damp patch and fit a plastic ventilation plug and await developments it may cure the problem you never know. post note the surveyor used an...
  2. S

    damp problems

    Hi Thanks for the reply I am now totally confused I thought that c/w insulation was blown in through holes drilled in the outer wall and would be forced everywhere in the cavity unless a barrier stopped this from occurring. The only way that I can see a barrier being installed is to either...
  3. S

    damp problems

    Hi I understand that installing cavity wall insulation can lead to damp problems I'm wondering if cavity wall insulation can cause the following damp problem On the south east corner of my detached house at the dpc level and slightly below I have a damp patch it extends for approx 6 bricks...
  4. S

    condensation problems

    Hi Thanks for the reply I was very careful to ensure that the ventilation of the roof space was not covered with the insulation but can I add my style of living has not changed apart from having dg replacement windows flitted also cavity wall insulation and increasing the insulation in the...
  5. S

    condensation problems

    Hi Can anybody resolve the following I've lived in this house for the past twenty five years and only in the past two years have I had a problem with condensation on the windows and in the loft. 10 years ago I replaced the windows with argon filled dg units which solved the small condensation...
  6. S

    Gas meter accuracy - fit another along side ??

    Hi I thought that checking the rated output of the boiler was part of commissioning. Full flame is easily achieved when you have a low starting temperature I have a modulating boiler and it always starts on full flame when cold and runs like this long enough to calculate the gas used if you...
  7. S

    Gas meter accuracy - fit another along side ??

    Hi Surely a quick test for the meter is to calculate the output from the boiler by measuring the volume of gas used when boiler on full flame and check against the manufactures output
  8. S

    changing heating controls

    Hi Sorry for the delay in replying but I have been away for a few days and have only just returned and read your post. The box I have is identical to the one shown on the diagram from Honeywell I can only say that I must have imagined the red wire terminal but it still has one more terminal...
  9. S

    changing heating controls

    Hi Yes I was confused as well The box is labelled sundial plan no42005748-001 I purchased it with the stat and valve from a heating controls web site but the strip to connect the mid position valve to has 6 connectors one being the red wire which doesnot appear on the valve I think I was...
  10. S

    changing heating controls

    Hi Thanks for the info Yes I have a smartfit y plan but it causes me problems I've had three room units in 8 years so I thought I would change to a standard y plan using the programmable thermostat instead. One more question I purchased a sundial wiring box but it has one more connection to...
  11. S

    changing heating controls

    I have just purchased the following items to change from a smartfit y plan v4073 valve, cm927 stat, cylinder stat and sunvic wiring box. I've been reading the various items concerning the cm 927 used on a y plan system and as I haven't got a cheap programmer would it be alright to use a...
  12. S

    retained air in system

    can anybody advise how to remove retained air in my heating system. Brief history Last year I had serious problems with my boiler and had to replace the heat exchanger and as the system never incorporated an aav I installed one as close to the boiler on the return as possible.At the same time I...
  13. S

    Manhole cover

    most builders merchants stock manhole covers and frames either in steel or grp.
  14. S

    installing tray with concrete ??? sharp or soft sand ?

    Do you intend to concrete a shower tray in or do the instructions say bed the tray on sand. If your fitting an acrylic tray onto a plywood base then to bed it on builders sand is the answer.
  15. S

    Running water to summerhouse

    Can I also ask at what depth are you burying the cable and what precautions are you taking concerning the protection against damage.
  16. S

    Running water to summerhouse

    Following the very hard winter of 1962-63 the failure of many buried water mains caused a rapid rethink of the minimum depth it is now a requirement that water supply pipes are buried at a depth of 1M
  17. S

    which tank to drain c/h system ?

    Hi I'm not a plumber or one of the wonderful heating engineers but draining and refilling a heating system can be full of woes and troubles if you are not careful. The small tank in your loft (providing you have a vented heating system) is known as the feed and expansion ( F&E) tank and is...
  18. S

    base exchange water softener

    HI Please consider the following and any comments will be gratefully received Base exchange water softener fitted to a combi boiler with a alloy heat exchanger I read somewhere that this will cause problems with the heat exchanger as the excess sodium will react with the alloy. If...
  19. S

    baxi barcelona problems

    Thanks for the info I have a couple of questions if its not to much trouble I thought it might be the burner as its such a fine ceramic one and I've always been very cautious about cleaning it just a very light brush with a camel haired paint brush. The heat exchanger on the other hand...
  20. S

    CAN I RUN A TELEVISION FROM A CEILING LIGHT ROSE

    Hi I haven't seen a 5a 2 pin socket outlet since I was a small boy about 55 years ago when it was the nom to plug the iron into the light pendent with an adaptor. How things have changed . I even remember removing capping and casing during my apprenticeship. But even then all...