Search results

  1. M

    Elkay programmable switch not working after blown bulb

    Hi, I have an elkay 790-2 that I use to control my porch light. I had a blown bulb last night which caused the fuse box to trip. I have replaced the bulb and reset the fuse but now the switch now no longer causes the light to switch on despite the controller thinking that it is switched on...
  2. M

    Drayton Lifestyle LP722 - not working?

    Hi everyone, Over the last week or so, I have had an intermittent fault with the controller not switching on the hot water. Sometimes it seems to work fine and start the boiler heating other times the red light goes on the controller but the boiler doesnt fire. What I have noticed is that...
  3. M

    Honeywell cm907 in conjunction with a lifestyle lp722

    Hi everyone... I wonder if someone can help. I have a fairly old standard gravity fed system. It is a Ideal boiler with a lifestyle 722 controller for hot water and heating with a separate mechanical room stat. Last week i had an electrician replace the room stat with a honeywell cm907...
  4. M

    15 litres per minute - enough for Unvented system?

    I am looking at putting in an unvented system but there are issues with water pressure. The water board have told me that there is three bar pressure at the main, so I can only presume that it is my pipe into the property that is restricting it. I get around 15-20l per minute. I have just...
  5. M

    Ideal istor 325 - thermal storage thing

    The time has come to replace my 197x ideal standard boiler (huge old thing cemented into the floor) and I am considering putting in one of these ideal istor 325. My friend has just had one put in and thinks they are great. It would be great to remove the old header tanks, etc. and have just...
  6. M

    Rising Damp or not?

    We have an victorian ground floor tenement flat that has mould appearing on the inside of the external walls of both the bedroom and living room (both have the wall running along the front of the property. This rises from the bottom of the wall up a couple of feet. I am planning to get a...
  7. M

    15 lpm mains pressure - is that enough?

    I am looking at replacing my boiler with a heat bank on a vented system or an unvented system. I had British Gas in yesterday and they advised me that my mains water pressure was around 15 litres per minute and that would really defeat the benefit of using one of these systems and unless I can...
  8. M

    unvented system with microbore?

    We have been in our victorian house for about 4 years and have decided to replace the boiler. The current system is a conventional vented system, microbore pipes and an early 70s ideal standard boiler and some old and some new radiators. The house is fairly large 4 bedrooms, 3 bathrooms and 4...