  1. S

    Myson Apollo 30si ignition sparking when pilot alight

    i've got a myson Apollo 30si boiler late eighties. Goes through the ignition sequence fan comes on and pilot ignites. it continues to spark repeatedly and main burner wont light. There are two solenoids on gas valve, i've got 240volts on pilot one and nothing on main burner solenoid. Air...
  2. S

    Faulty hot water on baxi 105 e

    Fitz 1 you are spot on mate. :D Min working pressure at gas valve was 10mbr. Adjusted it to 2mbr and hey presto boiler stays on, then adjusted max working pressure to suite. Ended up calling baxi tech and havent got back to site to thank you guys for your assistance. Thankyou all
  3. S

    Faulty hot water on baxi 105 e

    Thanks bengasman, i was 70% sure and don't really do a deal of breakdowns and this guy wont stand parts being chucked at it. Many thanks again . :D
  4. S

    Faulty hot water on baxi 105 e

    Yes mate tap and flow rate are plenty and when central heating is on boiler runs for a lot longer, untill up to temp.
  5. S

    Faulty hot water on baxi 105 e

    Hi guys wondering if you could offer me any advice ? A customer has had a mixer shower fitted not thermostatic, but compatable with a combination boiler ( manufacturers) hot water is getting hot but boiler is switching off every 40-50 seconds and goes off for about 7-8 secs. Ive tested both...
  6. S

    Halstead gold combi no power ?

    Thanks for that, it is the Halstead platinum model and i'm gonna have to give it the full monty tomorrow. Thanks again for your help chaps....
  7. S

    Halstead gold combi no power ?

    Has anybody got any links to halstead manufacturers instructions ? please.
  8. S

    Halstead gold combi no power ?

    Nothing at all, No noen lit when fuse spur and boiler turned on have checked all external electrics visually and fuses.Im asuming neon should be lit when powered up.air pressure switch or pcb spring to mind but i'll just have to check it tomorrow with multimeter. With it being a neighbour he'll...
  9. S

    Halstead gold combi no power ?

    I'm not sure of the model, it's the one where the on /off dial on the right hand side also incorporates a reset by turning it , like baxi 105. Yes im afraid i am corgi registered too, mainly boiler polishing.
  10. S

    Halstead gold combi no power ?

    Had a quick look at neighbours boiler just now,tools at work.checked mains fuses ok, fuse spur replaced 13 amp with correct 3 amp and even replaced internal fuse on pcb.before i go back with multimeter tomorrow,anybody aware of any obvious faults on this boiler ?
  11. S

    RAVENHEAT CSI 85

    Boiler was not responding to either of the hot water or htg boiler stats,consequently it was overheating and blowing the prv and going off on high limit. On advise i changed the micro switch on diverter valve and checked all electrical connections, unfortunately same thing happened. I've...
  12. S

    RAVENHEAT CSI 85

    Ok Boyo THANKS AGAIN and HAVE A GOOD UN
  13. S

    RAVENHEAT CSI 85

    Think i may have miss led you in earlier message. When boiler is run on hot water mode only, no taps open. Boiler comes on and overheats eventually releasing pressure relief valve and then shutting boiler off in high limit mode. Turning hot water stat off doesnt turn burner off, during this..
  14. S

    RAVENHEAT CSI 85

    Thanks Slugbabydotcom, the manual gives me something to go at..
  15. S

    RAVENHEAT CSI 85

    Boiler is getting up to temperature and going off on high limit. When both hot water and heating stats are off and boiler is set to heating/hot water or just hot water. It appears to just bypass boiler stats,also neon for burner doesnt come on and it does work. Looks to me like gas valve or...