  1. L

    potterton lynx 2

    do what right!!!!!!!!!!!!!!!!!!!!!!!!! ooh yes of course i see what you mean ......i will make sure i hold the pressure gauge correctly and do the risk asassessment before i stand on the stool and ooh yeah ask for a cuppa.......
  2. L

    Wickes combi 102 (Halstead)

    if the boiler only fires up when the combustion chamber lid is off then i would look at the flue for blockages, check the fan venturi for blockages . it is quite possible if all the above checkout ok then the fan or aps may need replacing.
  3. L

    potterton lynx 2

    thankyou guys i dont think its the gauge but worth checking and definitely worth checking the charge on the expansion vessel
  4. L

    potterton lynx 2

    water leaking from PRV, replaced with new PRV still same problem thought i had bought faulty PRV so replaced with another and guess what same problem, c/h and h/w working ok, pressure on gauge set at between 1.5 and 2 bar. lose about 0.5 to 1 bar pressure in a day all from the PRV. any ideas...
  5. L

    Ravenheat boiler

    i recently worked on a ravenheat boiler with a similar problem, it started the same way and came to a point where the light came on each time he came to use the boiler ie light basically was on constantly, the fault was cured by replaceing the overheat stat, the part would cost you around £20 to...