Search results

  1. A

    Marley Modern

    Thanks Steve, If laying right to left, I'll need to start at a valley and hence a cut (at an angle) tile. Does this not make it difficult to finish exactly full tile at the eaves? Or is that just the trade off of an interlocking tile. Do you remove the interlock at eaves? I'm just...
  2. A

    Marley Modern

    Hi and thanks to all that reply, I have a few questions about the Marley Modern tile and would be grateful of your input. Most roofing merchant websites direct you to the Marley website but surprisingly I can't find the answers there! Hope I don't confuse anyone! Here goes: 1) To create a...
  3. A

    16amp ring final?

    Thanks for the reply's, going to stick with the 16a and probably ponder the many possible reasons for the original de-rating!
  4. A

    16amp ring final?

    They are Wylex - good quality?
  5. A

    16amp ring final?

    That would have been easier! thanks. It wasn't to prove branches, just confirming the 2 circuits were a ring. I cannot prove the circuit hasn't been de-rated so am happy to leave the 16a MCB if the general consensus is it will not cause a problem.
  6. A

    16amp ring final?

    I isolated the supply, removed a double socket joined L and N for each leg and tested for continuity at the board if that makes sense.
  7. A

    16amp ring final?

    Thanks, I had considered that the circuit may have been de-rated and as the 16a MCB has caused no problems so far I'm happy not to have to confirm all the ifs! My only concern is for the MCB operating near is trip value. Do they not detect over current based on heat? Could this cause early...
  8. A

    16amp ring final?

    Hello and thanks to all that answer, I have a split load board with a ring final on each side. I noticed, the other day, that the ring on the RCD side has a 16a mcb. I know this is not usually the case and so double checked that it was a ring and not two radials. It is definitely a ring wired...
  9. A

    'heat resistant' terminal strips?

    The original connectors were clipped to the housing but i have used the existing plate to securely mount the connection strip. I think ceramic strips are the way forward, but will look to see if I can get a replacement from the manufacturer.
  10. A

    'heat resistant' terminal strips?

    Hello and thanks to all that reply, I've just finished replacing an oven cable from the cooker connection plate to the connection at the oven. During which I found the connection point (oven end) cracked and unsafe. I have used a terminal strip, of coreect Amp rating, to make a temopary...
  11. A

    wiring for lp111 and thermostat

    Thanks for all the input, Went with the lp111 and thermostat in the end, Only because they were already in the post form screwfix! All done today and working well. Further questions for you all if you fancy them: 1) Explain why the thermostst has a neutral, I think its for an...
  12. A

    wiring for lp111 and thermostat

    Any other opinions on this option(DRT2). I like the idea, nice and simple but battery operated puts me off, anyone used/installed these. Any comments welcome. cheers
  13. A

    wiring for lp111 and thermostat

    I'm liking the look of that! I got blinkered into fixing the programmer fault and then adding a stat. Instead of solving them both at the same time! Is this device widely used for this set up? thanks for answering the other questions.
  14. A

    wiring for lp111 and thermostat

    Hello and thanks to all that answer,this is a follow on from a post earlier this week but i've started a new thread to prevent confusion. I'm changing a broken drayton programmer (not digital) for a drayton LP111 connected to a vaillant . The backplate is wired exactly the same so an easy...
  15. A

    drayton timer problem?

    update- i'm an idiot! Linking 3 and 4 at the boiler now works, so its definately the timer! I'll not tell you my mistake because there's enough **** taking on this site so I won't open the floodgates for more! Will a newer, digital (drayton) programmer mount to the backplate already...
  16. A

    drayton timer problem?

    thanks, tried that still nothing. then i removed the external controls by bridging connections 3 and 4. still nothing. Any ideas??any thing else i can check myself before getting someone in? thanks.
  17. A

    drayton timer problem?

    hello and thanks to all that answer, This is an electrical question stay with it! I have a vaillant combi boiler which is not firing/pumping (heating) however the boiler is producing hot water and no fault codes are displayed. I have a drayton timer. sorry don't no the model number but its...
  18. A

    6KW hob... not cable sizing but as good as!

    hello and thanks to all that reply, I'm sure you've heard it before but this really is a story about a friend!! He's just redone his kitchen and had a rewire. the lecky has wired a socket for the connection of a hob from the ring main. However, the hob ,possibly unknown to the lecky, is a...
  19. A

    replacement glass

    Will be calling on monday with the measurements but as i'm not at the property, a friend is going to measure so wanted to give him as much info as possible. If there are no other comments to this topic will just measure the opening and ask them on the phone. thanks
  20. A

    replacement glass

    hello and thanks to all that answer! I need to replace a glass panel in a pvc door, sorry but i can't take a photo so i hope i give enough info! i bought the house with it boarded up. its the type were you fit the rubber seals from inside which seem to be present. I have contacted a local...