3 year old boiler. Customer reported poor hot water flow.
Checked burner pressure to find boiler is not modulating on CH or DHW. Burner pressure does not move from about 2 mbar.
21mbar available at inlet to GV. Suspected NTCs, Gas Valve, PCB
NTCs are fine: have run with spares outside of...