Search results

  1. I

    new question

    sorted problem with 242 trip was ..tripped...reset trip CH work ok but rads are sligthly cold at bottom..now when i use the hot water the water get extremely hot...and after turning it off the boiler vaillant 242 E pressure goes up to 3bar and the temp sors to 100 degree C ....any advise and...
  2. I

    vaillant 242E, 282E

    ok guys after testing central heating, ibleed radiators with air in atic room....the problem seems to happen after using hot water...the hot water get boiling ! and then after turning off the pressure builds and the temp shoot through the roof, if i then turn the central heating on it all starts...
  3. I

    vaillant 242E, 282E

    9ok top right was a black boox with trip reset it its all ok ,and all working fine even on hot water pump is flowing possible air lock caused this/?
  4. I

    vaillant 242E, 282E

    ok thanks ill try both!!
  5. I

    vaillant 242E, 282E

    the smal black 2 wire over heat trip ,which looks much like the ones we use on wabasto cab heaters
  6. I

    vaillant 242E, 282E

    ok so if pump is in op the system wont fire?
  7. I

    vaillant 242E, 282E

    once they trip are they then replaced because last night i just bypassed it using a amp meter, IM a auto electrician and have fixed my older boliers potterton but this is way more advanced. lol
  8. I

    vaillant 242E, 282E

    dont know what any of them did.....whats the normal fire sequence i.e pump then ignite fan etc...and how do i test the over heat trip?
  9. I

    vaillant 242E, 282E

    no nothing the boiler is silent np pumps nothing work ch a no go to, once it over heats does it not reset its self?
  10. I

    vaillant 242E, 282E

    pressure is 2bar....and when it did happen i noticed the temp gauge was near 90 degrees after i got to the atic
  11. I

    vaillant 242E, 282E

    Hi guys, I have a 242e or a 282 e it lists both on the casing which wont supply hot water or heating ,all fuses are ok and the red switch is lite. It stopped working after i turned on the hot water ..after this there was a banging coming from the boiler and now hasnt worked since please...
Back