  1. K

    Ideal Isar problem

    Ok I have an engineer coming out on Monday and will let you know the issue/fix
  2. K

    Ideal Isar problem

    Ideal Isar HE30 Hi all we have this boiler - im aware that this boiler ain’t the best but when I call for central heating the burner lights up for about 30/40 seconds then goes out - fan continues to run then after 2 minutes the burner kick in again but for about 40 seconds then goes out - is...
  3. K

    Replace Honeywell R6660D with Drayton Wiser Multizone Thermostat

    All wired and set up perfectly - thanks all for the advice (y)
  4. K

    Replace Honeywell R6660D with Drayton Wiser Multizone Thermostat

    Thank you for the info - will set it up hopefully over the weekend and report back(y)
  5. K

    Replace Honeywell R6660D with Drayton Wiser Multizone Thermostat

    I have the above wiring and also wish to connect to the exact Drayton Wiser as above - can someone please tell me where the wires go on the new Drayton
  6. K

    Noise from shower until hot water - Grohe Automatic 2000

    A banging noise - I have emailed Grohe and they suggest the non return valves are faulty so will replace these and let you know Ken
  7. K

    Noise from shower until hot water - Grohe Automatic 2000

    Hello I have the above shower and have a problem where there is a horrible noise in the pipes around the shower until hot water comes out of the shower head - then it stops The shower is powered through my central heating boiler (new Baxi combi) - before that i had a vokera with the same...
  8. K

    Hoover S220 Washing machine fault - NOW FIXED

    It was the PCB board
  9. K

    Hoover S220 Washing machine fault - NOW FIXED

    I have the above washing machine and have a problem Half way through a programme I switched it off a few times and now it will not work - it fills and drains OK but wont start. The brushes seem fine and the motor is 12 months old - any suggestions? Ken
  10. K

    banging pipes - Water hammer?

    Its a Vokera 20/80 flomatic
  11. K

    banging pipes - Water hammer?

    The banging noise only comes when you turn the tap ON and not OFF I have read that water Hammer is caused by turning the tap OFF
  12. K

    banging pipes - Water hammer?

    If its plastic clips - then I can do that myself - I just thought it may have been a bit more of a technical issue involving pipework. Incidentally, looking at water Hammer - isnt that caused when you turn the taps off and not to on as is with my case?? Thanks for your input and will have...
  13. K

    banging pipes - Water hammer?

    the water cpmes straight from the main into a combi boiler Is that all it need pipe clips - why am i being charged 92 quid for that :o
  14. K

    Vokera Flowmatic 20/80 - any service engineers in brum

    Anyone in the midlands area that can give me a quote to service my Vokera Thanks Ken
  15. K

    banging pipes - Water hammer?

    When I turn the shower on or a hot tap I get a massive clanging noise and have had this for several months - I am now in a position to get this fixed and called a plumber for advice. He said its most probably water hammer and said that I will need 1 or two devices fitted in to the pipes to stop...
  16. K

    Vokera 20/80 Flowmatic hot water problem

    I have just checked the pressure with the gauge and its spot on. It looks to have beat me and will have to call an engineer
  17. K

    Vokera 20/80 Flowmatic hot water problem

    Yes I have checked this already and seems ok I am going to check whether the DHW expansion vessel is pressurised and am waiting for a gauge - I have noticed that there is a much bigger red Expansion Vessel that has been fitted so will check it also Thanks guys any more suggestions welcome...
  18. K

    Vokera 20/80 Flowmatic hot water problem

    Thanks - where is the secondary heat exchanger is it the white tank with the air bleed on top - here is a similar boiler on ebay - can you let me know where the secondary one is Cheers Ken...