    Identifying source of dripping water on unvented system

    Thank you Madrab, what you say makes total sense. I did think that there should be a second tundish as I have seen 2 on photos of other people's setups online. You're also right that it hasn't been called out durimg servicing. I'll make sure the engineer sorts the issue. Thank you once again.
  2. F

    Identifying source of dripping water on unvented system

    I forgot to add, that the dripping has been happening since I bought the housein 2021, and has not changed following each annual servicing. The system was installed in 2020. Thank you.
  3. F

    Identifying source of dripping water on unvented system

    Good morning eveyone. I'd like to ask for your thoughts and opinions please on identifying the source of water dripping from an external copper pipe please. In my townhouse I have an unvented system with a gas boiler which is made up of the following. Ideal ICOS HE15 condensing boiler...
  4. F

    Odyssey 1E to Reson8 tamper issue

    Thanks for your reply. It is the Reson8 that is making the unusual sound. I don't own a meter (yet) so can't take readings at this stage. I have had this panel running the same Reson8 sounder as sounder 2 and a Pyronix Belle as sounder 1 in the past (in the old house) and that setup worked OK...
  5. F

    Odyssey 1E to Reson8 tamper issue

    Thanks for your reply. I forgot to mention that I did also try the other way round (Sounder 2's neg hold off (Green) wired to A at panel. Sounder 1's tamper return (Yellow) wired to T at panel. The RTN- (white from sounder 2) and the neg hold off (Black from sounder 1) both meeting at the...
  6. F

    Odyssey 1E to Reson8 tamper issue

    Hi. I have an issue wherein whenever I connect the tamper from sounder 1 (Texecom Odyssey 1E) to sounder 2 (ADE Reson8), the siren in sounder 2 makes a strained 'squealing' noise (not the normal siren sound). The panel is a Honeywell/ADE Accenta G4 Mini. The LCD RKP shows 'Tamper Fault...
  7. F

    Help with existing alarm connection to fuse box

    Hi. A friend has recently moved house, and I decommissioned and removed the Accenta G4 Mini alarm system that I fitted for her a few years earlier. She would like me to fit this system into the new property for her. There is already an old panel (Texecom Veritas:cool: in the new property which...
  8. F

    Wiring Texecom Odyssey 1 to ADE Reson8

    Thank you both very much indeed for your kind help. Gary
  9. F

    Wiring Texecom Odyssey 1 to ADE Reson8

    Hi. Many thanks for your quick reply. I'd just like to clarify - do you mean yes I have the wiring right, and I do not need to use the microswitch connection? I can post some images from the Texecom Odyssey manual tonight if it will help. Your help is greatly appreciated. Thanks again, Gary
  10. F

    Wiring Texecom Odyssey 1 to ADE Reson8

    Hi all. I have to wire up a Texecom Odyssey 1 sounder at the front of the house, and an ADE Reson8 sounder to the back of the house. The panel is an Accenta G4. This work is necessary due to a house move by my friend. I would like to ask if someone could please cast their eyes over my plans to...
  11. F

    Accenta G4 blowing a fuse

    I just went and checked and the panel does not have a speaker fitted - the RKP acts as the internal sounder. I did notice that after I had checked the other two PIR's and closed them again, the RKP still showed '2: Setting Fault - Hall' upon trying to set Program 1. I tried setting...
  12. F

    Accenta G4 blowing a fuse

    I have now also checked the remaining PIR's and their wiring is also in order. @sparkymarka - not a silly question at all - I hadn't thought of disconnecting the speaker. I will do that tomorrow and report back. Thank you.
  13. F

    Accenta G4 blowing a fuse

    I have an Accenta G4 mini panel running 4 PIR's, 1 PA button, 2 sets of door contacts and 2 bell boxes which are in SAB mode. I installed this system in December last year and it has been working fine up until about 1 month ago. Upon going to set the system under Program 1 which is the...
  14. F

    Isolation valve replacement

    Thanks for the replies so far folks. I could tell that the setup didn't appear right when comparing it to a proper filling loop, but didn't realise it was against water regs. Unfortunately he always treats the prv like a drain valve whenever the system pressure needs lowering, so it too has...
  15. Puma 100 Filling inlet

    Puma 100 Filling inlet

  16. Puma 100

    Puma 100

  17. F

    Isolation valve replacement

    Hello again folks. I'd like some advice please if I may? My Puma 100 combi never had a 'filling loop'. Instead, there is just a single isolation valve in between the mains feed (on the left of the picture) and what I presume is the CH loop (on the right. This is the 22mm pipework that goes...
  18. F

    Cable tacker problem

    I checked the plunger and it does go right to the end. I applied a bit of WD-40 as advised, and I managed to get it to fire staples and tack reliably when tested. It seems that the problem occurs if I put in more than around a 2'' length of staples. So I've been putting just short lengths of...
  19. F

    Cable tacker problem

    Hi. I'm having a problem with a cable tacker (a Draper Expert ST3). I cannot for the life of me get it to fire staples! Here's the story; I haven't used mine since the 90's and as a result the spring on the cable retainer lost it's tension. So I decided to buy a brand new one. I loaded it...
  20. F

    Wiring Pyronix Belle to Honeywell Accenta Gen 4

    With specific regard to the existing sounder; I took the cover off The Pyronix Belle and I can see that it there is a jumper fitted over the two 'SCB OFF' pins. So I take it this means it is configured as an SAB? If so, that would make sense as its the only sounder. Its just that the Belle...