  1. A

    Stud Partition Poser ...

    You will of course be seeking Building Regulations Approval for this work? You will otherwise be contravening the Law.
  2. A

    air brick another question

    You will definetely need an air brick. This is normally provided by drilling a veny through the wall above the skirting on an external wall. You will need to get a Corgi Engineer to advise you. A Chimney is not enough as it extracts the fumes and needs make-up arir to work. Ring the GAs...
  3. A

    earthing

    Look at IEE Regulations
  4. A

    Cooker Amperage

    You should use 6mm preferably. You can get away with 4mm if it is a short run, but I wouldn't risk it for the extra cost. It will give you the ability to increase the size of the cooker later to 45amps and alot are 45+ amps.
  5. A

    TP10 and cable

    Is it coloured? i.e. is it a non flamable type? Are you using a breather membrane? Is the cavity you mention to be ventilated? Is the timber you are using treated? What is the construction of the existing wall? You do not explain why you are doing this. Are you following a manufacturer's...
  6. A

    consumer unit tails

    You must not break the seals. Contact your Electricty Board and they will send an engineer to reconnect the tails and test the board for you. DO NOT Meddle with the Meter, Mains Fuses or Tails. You will normally need 16mm or 20mm Tails. The Meter, and Mains Fuses are the property of...
  7. A

    12v transformers

    I agree either use one solid state T/Former per lamp or maximum of say 4 lamps. Otherwise if the T/Former fails you will lose all of the lamps. Also look for units with Soft Start and inteligenyt output so that if lamps fail the output is reduced to save power. Look here and here...
  8. A

    Any help with a dead nightstore heater

    Be very careful with Night Storage heaters, especially old ones. Many Old ones have asbestos in them!
  9. A

    Potterton Suprima tripping out

    Yes you are of course right, but have desoldered them to test. Red 2 Purple 7 Orange 3 White 0.01 Silver 10% Gold looks like BUT Orange? 15 here and here seem useful sites Have a Maplin...
  10. A

    Potterton Suprima tripping out

    Hi the same problem has been plaguing us too. First of all replacement of the Thermistor did the trick £8.80 But problem came back after 6 months. Its not the Overheat thermo approx £6 These are both easy to replace and test. Thermistor pull out on plastic clip. The overheat...