    Outside electrics - cable size?

    Nothing high powered certainly no heaters the livestock have feathers to keep warm!! The main reason for putting electrics over is to provide lighting and just put the sockets there for future use. Ive heard from someone else that i may have to put a local earth spike in due to the livestock is...
  2. D

    Outside electrics - cable size?

    I intend to run a swa cable from my house down to the stables run is about 75mtr. It will only have light usage say 3 lights and 3 double sockets. My question is what size swa shall I use?
  3. D

    AC supply for wired alarm system

    Im about to install a Galaxy 16+ system to my house. Everything else im cool with but was just wondering the best way to connect the main AC supply. Was going to fit a fused spur but this could easily be turned off by anyone breaking in. That said i suppose they could also switch of at the...
  4. D

    Galaxy 16+ manual

    ok like daisy changing a couple of PIR's then for instance. Im sure this will raise some eyebrows with some of you?!! If it works though y not!
  5. D

    Galaxy 16+ manual

    yes but the less i have will increase my chances of getting broken into wont it & the alarm not activating? a double edged sword i guess!
  6. D

    Galaxy 16+ manual

    Sorry for that! Hope you can both kiss and make up! Ah i see yeah a pic would be handy any idea of cost or where i could get one? Are the bgd any good? Was gonna put it in my kitchen extension as i have a large DG window and full DG door plus DG skylights so lots of glass but i was also...
  7. D

    Galaxy 16+ manual

    I seem to have started quite a discussion between you two here haha. Can either of you tell me if i can add more sensors to my system primarily 3 more door/window contacts and 1 more pir? cheers in advance.
  8. D

    Galaxy 16+ manual

    Thanks for your Input Atilla I personally think that the tones from my keypad will be ample as this will be fitted in the hallway. So i can fit the internal siren aswell as the external! gr8 i can defen the beggers if they try comin in.
  9. D

    Galaxy 16+ manual

    Ok breezer thanks for that. I think the internal siren was connected in parallel with the external before.
  10. D

    Galaxy 16+ manual

    sorry 16ohm? ok
  11. D

    Galaxy 16+ manual

    i gotcha. so you dont think i should bother with the internal sounder? just get a 8ohm speaker?
  12. D

    Galaxy 16+ manual

    the mk7 control panel beeps i asumme this will do.
  13. D

    Galaxy 16+ manual

    whats the speaker for breezer?
  14. D

    Galaxy 16+ manual

    sure in what way? I know its the correct one yeah
  15. D

    Galaxy 16+ manual

    Breezer cheers for the help so far. Could you post me the url for your sticky on uk electrics? sorry if that sounds lazy. ***removed*** Also if anyone else out there has the mauals they would be much appreciated. To sum up below is what my system comprises of. 1X GALAXY 16+ WITH...
  16. D

    Galaxy 16+ manual

    Also any chance of the connection drawing? I think i should be ok with the programming. "Hopefully" Thanks
  17. D

    Galaxy 16+ manual

    Ok i see well hopefully il get on ok. I cant moan much i suppose as I have the same policy when it comes to my stuff. Not sure to start with where and when to use the resistors.
  18. D

    Galaxy 16+ manual

    Breezer, Well my Dad had it taken out of his place when they moved. I now want to install it in my house and although im a electronics engineer by trade i think im gonna need the installation manual and engineers manual to get it all connected up and programed. Cheers
  19. D

    Galaxy 16+ manual

    Can anyone out there provide me with a installation manual for my Galaxy 16+ system. I have the engineers codes & manager code & the software but no manuals. Cheers peeps
  20. D

    Hoover AI 130 01 Fault

    Can anyone help please my Hoover AI 130 01 has developed a fault where it will not complete programmes 1-11 which are the most freqently used cotton programmes. Quick wash and sportswear wash work perfect so im guessing its the Electronic control module. Does anyone have any views on this? also...