Search results

  1. M

    Miele W828

    Just a quick re visit to the thread .Ive replaced the faulty relay and fuse ....after doing the brushes . All back together, power it up and.......flashing rinse lamp....... :evil: Whip the motor out to check the brushes are seated and lo and behold one of the spade connectors on the...
  2. M

    Miele W828

    Another Post to say thanks for this thread. Not repaired it yet ,all the same symptoms as the other complainants ,so I'm confident a new fuse and relay from Farnells will sort the problem. Already changed out the brushes as that was my first port of call. Top work folks
  3. M

    Electricians

    I used the holycroft for the trial period and found it to be pretty good,I then bought a megger mft 1503 and managed to get a good deal on the meggar powersuite pro software ,which can be used on a palm reader,or laptop,and the test results can be bluetoothed from the tester staight to the...
  4. M

    Ceiling downlight trend

    They have...sheet of plasterboard,starett cutter and a short piece of 50mm batten.,and some poly filla :lol:
  5. M

    Unbelievable

    But whitgum never said pop to the hardware shop for a compression cap......did he. :roll:
  6. M

    Converting y plan to s plan troubles

    Thats excactly what I did. The neutral is common at all points,so It really didnt matter where i picked it up from. I originally had the pump running from the wiring centre but wasnt sure whether the pump would still over-run. pah...central heating wiring its a doddle :lol:
  7. M

    Converting y plan to s plan troubles

    Thanks for that gasman...just finished wiring in the ufh manifold too,and its all working a treat. I had it all sussed ,except for the additional swl/pump overun terminals on the boiler,that the honewell diag didnt show. I have the full wiring diag. for wiring up an ufh system if anyone...
  8. M

    Converting y plan to s plan troubles

    Can any of you electrical /plumbing chaps help me out,I`ve had to convert my y plan to s plan to add an additional zone for an underfloor heating system(dont get me started on that particular project :evil: ) heres my trouble....where do I pick up the switched supply to the boiler panel...
  9. M

    Honeywell V4073 Mid-Position Valve - any experts?

    oops should have been my own thread ..sorry
  10. M

    Underfloor heating control

    Thats exactly what I`ve fitted , nice tidy package,built in Grundfos pump,flow and return temp. gauges, flow/mix valve ,over temp cut out etc. I`ll post up a pic tommorrow. I fitted a honeywell auto bypass valve between the flow and return.It`s just this mixing of the two types of control I`m...
  11. M

    Underfloor heating control

    Firstly hello . Hate to start DIYnot forum life with a question,but needs must. Can any plumbers help me with a problem I have .I have recently installed an underfloor heating system to the ground floor extension of my house (approx 45m2) The manufacturers instructions state that it can be...
Back
Top