    What type of boiler is this??

    Could someone identify this boiler for me please? The Burner is a Riello G3B Firebird 90K. I need to buy a nozzle. I'm thinking of getting a 0.65 60deg but am not sure. //www.diynot.com/network/omo/albums/
  2. O

    Baxi 35/60 won't fire up

    At last I have found what was wrong with baxi 35/60. One of the 2 blue wires coming back to the pcb from the over temperture heat stat was intermittently going open circuit. So hard to find this out and was jammy to find it in the end. Having replaced this stat when the fault occurred...
  3. O

    Baxi 35/60 won't fire up

    Could you tell me where the Boiler stat is positioned. I can't see where it is on the schematics. Also what readings should I be expecting to see if it is/not functioning. Thanks.
  4. O

    Baxi 35/60 won't fire up

    Hi Chris, I did change the safety thermostat recently so would you reckon that I should flush out the system now and/or change the pump at this stage. Mike
  5. O

    Baxi 35/60 won't fire up

    Could somebody explain what this fault could be with my Baxi 35/60. On initial start up the boiler works perfectly but on reaching the required temp ~70-80 deg C it shuts down on both flame failure and Safety thermostat faults.The pump continues to run on for a few mins but when the temperature...
  6. O

    baxi 35/60 shutting down on safety stat fault

    Sorry Tony I didn't explain this properly. In the manual it states Allow system system to cool,If the continuity across thermostat terminals is more than 1.5ohms then replace the Safety thermostat. I was measuring around 16 ohms across the stat so I bought a new one. Before installing this I...
  7. O

    baxi 35/60 shutting down on safety stat fault

    I have a Baxi 35/60 which will shut down frequently and the neons for both flame failure and safety thermostat activation flashing. On consulting the manual I measured a high resistance across the safety stat so I replaced it. Before replacing it I measured the new stat for resistance and it did...
  8. O

    Vokera 14e not firing

    I've no idea what he did as I wasn't there to see. Is this overheat stat the reset button on the front panel or is it in the boiler. I pressed the reset button on the front panel for a few seconds but to no avail.Could you tell me if there is such thing as a sealed system that is able to top...
  9. O

    Vokera 14e not firing

    I have a Vokera 14e which when I turn on I can hear the fan a pump running. The fan and pump remain running but the boiler will not fire up.Pressure on boiler reading below .5bar.I had this problem before on a different boiler and what I used to do was turn open a valve in the hot press to...
  10. O

    Vokera 14e not firing

    Pressure on boiler reading below .5bar. I can't find a fill point to top up system so as to ignite boiler.Is there another option to fill system