  1. C

    Worcester 24i RSF-L Combi boiler problem

    Was unable to repeat the problem last night and the system worked fine. Obviously a problem is evident and I will have to monitor it. Best Regards.
  2. C

    Worcester 24i RSF-L Combi boiler problem

    Thanks for the reply. We do live in a hard water area so a scaled up heat exchanger could be the problem. If this is the problem what would be the remedy? I will try running it after it goes cold tonight to see if it heats up again.
  3. C

    Worcester 24i RSF-L Combi boiler problem

    Worcester 24i RSF-L Combi boiler problem: When I turn the hot water tap on the boiler fires up and hot water is dispensed from the tap. However after a minute or two the water goes cold. Is this a diverter valve problem? The boiler also makes a noise after I have turned the tap off that sounds...
  4. C

    Electrical Testing

    When work is completed on an installation that requires electrical certification can a person who has completed the C&G 2391 Inspection and test of Electrical installations complete the tests required? However this same person is not certified by a professional body (NICEIC) can they still...
  5. C

    Swimming pool light

    Thanks!
  6. C

    Swimming pool light

    The pool would be empty prior to fitting.
  7. C

    Swimming pool light

    Has anyone ever fitted a submersable light in a swimming pool? If yes can you please advise on any potential problems and possibly a method to fit. Thank you.
  8. C

    Socket Spur

    I rewired the spur and everything works. As you stated there must have been a short in my original spur wiring. One thing that should be noted is that my measuring instrument has the facility to detect a live conductor, measure voltage, detect resistance (impedance?) and continuity. However when...
  9. C

    Socket Spur

    Thanks for the quick response. There was a black mark on the wall around the socket where the spur was being taken from. When I removed the socket the insulation on the live and neutral wires going to the socket spur had overheated and was out of shape (melted also when I went to disconnect the...
  10. C

    Socket Spur

    I have added a spur from an existing socket that is on a ring. I have performed continuity tests to confirm that the existing socket is part of a ring. There are 2 cables coming into the existing socket. I have an older style CCU where overcurrent protection is provided by fuse wire that is...
  11. C

    Cable Tray

    Thank-you
  12. C

    Cable Tray

    Can steel cable tray be used as a CPC?