Search results

  1. F

    Worcester 24i Combi - strange water leak.

    Because of expansion when hot,As you know when things get hot they expand and when thos happens its causing the connection to leak.
  2. F

    Help! My Ideal boiler won't switch off

    If like alot of systems everything goes through your mzv then as the lads said ,it will be the switches stuck and as it will stop and cool down then fire up,the stat seems ok give it a wack
  3. F

    Air in hot water flow.

    I get these now and again,no hot water out the bath tap,its ok everywere else,and they look at a fault with the pressure or boiler(combi),and when you ask"is the tap ok" "oh yet,didnt think"so i say tap faulty
  4. F

    Worcester bosch 280rsf please help

    NIGHTMARE,if it is d/valve its a remove ex/vessel job.Its a pain,i think a sunvic head does it as well.if you can just change that,pain in the arse
  5. F

    Worchester Bosch 28i Junior OR 30CDi?

    One bathroom,so as the junior will do exactly the same on heating side,and you have the normal amount of h/w draw offs a 24 i junior would do it but as you mention 28 i,that will be plenty,ive fitted over 200 24/28 i juniors since they came out around 2003 - 04 and are great boilers,the cdi...
  6. F

    Worcester 240 pump?

    It might not be your pump if its running fine seperatley,is there 240 v when its not spinning.if there isnt might be pcb,if it is check for sludge
  7. F

    Badly installed systems

    I would like to know ,what is the worst condition you have seen a system in ?. I went to a job were the girl told me "I think the rads are going to burst". I went and found single rads had swelled out to 15" in depth,so it was 17" off the wall,system 4 yr old,i found leaks under the floor,so...
  8. F

    rads lukewarm

    I would ask him to just make sure its balanced,and it should be fine,get inhibator in the system as well.Its vital you get it in,your system can last years and years or go after 5 yrs,if its not protected,i seen rads 4 yr old,swell from normal to 15 " it had gone like that through the system...
  9. F

    Best way to advertise

    I believe advertising is very very important,unless your the only firm in your area,which is unlikely,you see B/gas,advertise everywere even though there the biggest around.I would get in the yellow pages,and get your van signwritten,i have one van but people say "see your vans everywere".Im on...
  10. F

    rads lukewarm

    mcandrew,turn the lower levels off by new trv and then close upstairs rads ,open one of them not working,then leave open and go to next rad and open and so on.I would close both ends on all rads and let system cool,then start at the top,open trv fully,then the other end called lockshield...
  11. F

    Hiding Gas pipe

    NO,GAS4U,i am not anyone else,so please dont start thinking about ignoring me or replying in ways you do to people who are a pest.I thankyou chris,2 days and your after my blood,grow up eh son
  12. F

    OLD PIPEWORK,ONTO NEW COMBI,?

    I done a boiler change in july,combi in place of conventinal baxi.I told the customers there old pipework may be in line for replacement as it could start leaking. I was told" october,we will ring you and get it replaced".I said the rads should be ok,all were 12 years old ,swapped when baxi was...
  13. F

    Baxi 105e problem

    Sounds like plate heat ex might be blocking up.I WOULD look into a couple things first,fan is it ok,keep running and if so check venturi ,aps,this is a corgi mans terrority,a pcb it may be but there is lots before i would swap that
  14. F

    Why do I need a new bolier?

    Elaine not all men are pigs.I am disgusted by this,who see woman as a free ride. I will accept a cheque for this advice £250 thank you
  15. F

    Hiding Gas pipe

    Sorry,im confused ? who am i ? were am i ?. Ive seen you do this to new members ,before i joined up,i would have a look and see you doing this.I am who i say i am,i dont care if you think im a rudeboy,keep your sexual tendancies private please
  16. F

    Replacement Boiler

    Really? I thought they were superb,the whole thing i liked from the flue to the casing.I am really suprised,by your replies.I have fitted 5 and now i wait for the leaks to start. Is the c55 a culprit as well
  17. F

    Why do I need a new bolier?

    I would ring them and say "I have had more qoute's from local firm's and they have told me the repair's are minor and as im covered,you should repair it". I had one last year,a 80 yr old lady,her floorstanding boiler had been leaking,she was with British gas,so they visit her and tell her, her...
  18. F

    Hiding Gas pipe

    I can see that gas4u,i appreciate the tip.I was really under the impression gas had to be protected.I havent ran much gas pipework outside that was on show,any i have has been boxed in
  19. F

    Replacement Boiler

    I would advise you to just have a look at keston boiler's.I have only installed 5 of these but they are amazing boiler's.I fitted one last month in a church that had 14 big rads,10 were large double's,and i fitted new cylinder ,this was a pressurised system,so it needed a ex vessel and i was...
  20. F

    Hiding Gas pipe

    I got called to do a gas carcass at 3pm last month,needed to be in by 5pm,so i got my 22mm and bending machine out ,few couplings and after 15 min i got 3 rolls of denso out and covered the pipework very well.I had pressure tested it before denso went over the pipework and then i used nail ins...