Search results

  1. J

    no power

    Is it tripping an RCD on your board. If so un plug all kettles toasters, fridges, washing machines, heating elements. Then turn on RCD and plug in and test each item one at a time, this will then let you know if you have a faulty item. Leave that un plugged and all should be ok...
  2. J

    Intermittent lockout on worcester heatslave 15/19

    You appear to have been spot on, i check it when all is ok and it gives me about 2.7K ohms, when the tone changes i pull the plug and check it again and i have nothing just open circuit, then as it cools i once again 2.7K ohms, this falls conveniently in line with the satronic box resetting, do...
  3. J

    Intermittent lockout on worcester heatslave 15/19

    It does reflect my occupation, that is why i was curious about the wording as i know when i deal with gas solenoid valves and such that i normally get continuity. Now you have explained what you mean i understand what you are saying, if the solenoid is on it's way out the coil will break...
  4. J

    Intermittent lockout on worcester heatslave 15/19

    What do you mean when you say continuity, or do you mean voltage. I should have continuity at the oil solenoid because it is a magnet which will give me continuity. I am about to put a cable in the oild solenoid terminal so i can check for voltage when i hear it shut off. I have just...
  5. J

    Intermittent lockout on worcester heatslave 15/19

    I have a heatslave 15/19, it all fires up ok and runs for about 5-10mins, then as i am watching it, i hear the oil pump shutdown and the fan continue to run, the satronic box appears to start driving then when the satronic control box reaches the end of it's cycle it goes to lockout. I wait for...
Back