    hot water pressure in kitchen bad/bathroom fine? what to do?

    HI pressure is always issue with these systems.you might need 22mm pipe all the way.i think old pipework has too many bends/elbows.
  2. L

    Changing Kitchen hot water pipe

    HI depends on the distance usually 15mm is ok .if possible always insulate to keep water hot. copper/plastic same. i prefer plastic
  3. L

    Grasslin programmer help

    HI if you ring manufacturer they will be able to tell you whether it will be compatible .otherwise you can always fit different models but it will take a lot longer to fit.make sure you take pics number/label wires before removal
  4. L

    how to refill Vaillant Turbomax 824E

    HI a picture would help with these particular models there are two slots.you can use special key or a flat screwdriver. if you look carefully you will find another one as well
  5. L

    Fordham bi folding shower door spare parts

    HI difficult to find might be better to fit new door
  6. L

    rangemaster clasic 90

    HI 1.spark gen. faulty 2.spark button faulty/pressed when not required
  7. L

    Ferroli modena - cutting out when switch hot water tap off

    HI one of the sensors might be damp/wet or faulty difficult to tell without looking /checking
  8. L

    Ideal HE24 Boiller what does the expansion vessel do?

    HI why did you pump air in E.V ? put that piece of junk in the bin . banging noise when firing usually relates to 1.faulty gas valve /setting 2.electrode faulty 3.p.c.b faulty
  9. L

    Shower pipe sizing

    HI 22 mm upto the shower is better than 15mm.you will see the difference in water pressure.and make sure you shower is suitable for low pressure system as most showers are for high pressure .
  10. L

    U16 GAS RATING

    HI can someone help me with U16 gas rate .i have chart for U6/E6.is it same or different ? SORRY ,MOVED TO COMBUSTION CHAMBER.
  11. L

    My central heating is taking over my life!!

    HI if your house is new then surely boiler or the system has become faulty.forget the 17/19 deg temp at the room stat.room stat could be few deg out of adjusment. al long as your room stat is on/calling for heat the boiler/rads should be on.
  12. L

    Leaking boiler

    HI which inlet valve ? Might just need washer/ptfe
  13. L

    Fitting radiator. Is it worth flushing system first?

    HI empty the tank .use sponge,etc clean the tank.then drain through various rads downstairs/lowest point few times until water runs clear.then add sentinel cleaner leave it running for few weeks then flush again few times.finall add inhibitor. FED UP OF COWBOYS ? TRY INDIANS
  14. L

    New Radiator heats up fully then goes cold after 2 hours

    HI simple balancing required FED UP OF COWBOYS ?TRY INDIANS.
  15. L

    Chuffing Baxi Solo 2 Boiler

    HI then i suggest that you check the noise from zone valve/three port valve.
  16. L

    looking for a shower pump and would appreciate some advice

    HI cheack mira enhance and you can also fit descaler on the pipes
  17. L

    Potterton Ultra2 shuts off after 10 seconds

    HI can be many things aps pcb fan coil hw/ch sensor
  18. L

    Are monobloc tap inserts all the same size?

    HI all different sizes.huge range.
  19. L

    Fitting thermostat to Saunier Duval F30e plus

    HI thats fine i have check the manual connect where the link was .if you struggle with room stat just buy standard honeywell(T6360B) room stat and use 3 and 1 pins.
  20. L

    water hammer .....

    HI come across this before.washer in the mains stop tap loose/worn.even better replace the stop tap.i was taught this in college.