Search results

  1. S

    Salus EP200 & Stat RT300RF wiring question

    Hi I think I fixed it! I had the T4 and pump both in NO Now I have the Pump in NO and T4 in COM Thanks
  2. S

    Salus EP200 & Stat RT300RF wiring question

    Can Someone help me I have the same setup Gravity fed water, pump for CH I have Salus controller RT300F wired as follows Pump to NO (top right) Boiler to common (middle) T4 from programmer to NO T3 from programmer to Common Water works fine With CH on pump on all the time? I have...
  3. S

    lintel above window

    Yes no lintel above 3m window but no cracking or movement either strange? Original above the window was a flat roof which was built upon but no lintel put in? The window above has a lintel I hope you are right about the concrete lintel on the inner wall? No planning permission required I...
  4. S

    lintel above window

    Yes that is exactly what I want to do and I have been recommended to fit a heavy duty lintel for the outer wall only not the inner cavity wall?
  5. S

    lintel above window

    Recently had a window replaced on the ground floor with french doors size 3050mm x 2100mm. Apparently no lintel was found? Now wish to have window above replaced with inward french doors so wall has to be removed with window above and lintel and french doors put in place Seem to be getting...
  6. Untitled

    Untitled

  7. window

    window

    lintel/ french door problem
  8. Untitled

    Untitled

  9. window

    window

  10. S

    Radiator valves

    Hi, Some of my radiatiors dont seem to have a lock valve to close one side has a rounded point that can be pushed in but springs back out Never seen these how do I close them off Thanks :(
  11. S

    LOFT CONVERSION

    Hi, I wish to lay 8x2 floor joists next to the current 4x2 for a loft conversion The span from the back wall to an internal loadbearing wall is approx 3.3M so C24 should be OK Currently there is a Purlin wall built supporting the roof on each sides The wall is embedded in the external side...
  12. S

    GARAGE DOOR INFIL

    Does anyone know if it is possible to build a half height lightweight timber framed infil for a garage door with windows above and the appropriate insulation that will be accepted under building regs as part of a garage conversion?
  13. S

    DPC FOR GARAGE FLOOR

    Hi, I am due to start a garage conversion and will be raising the floor by using 4x2 battons place on top of the concrete slab with sealed insulation inbetween and then topped with chipboard. I have had conflicting advise about the polythene DPC whether it should go under the battons on the...