Search results

  1. C

    No hot water

    I have tested the only thermistor on the boiler and its working to its specification. The problem only arises once the boiler is up to its highest temperature. This happens in c/h and d/h/w mode, fires up then shuts off.... Repeats This one has me?
  2. C

    No hot water

    thanks for all the help. I am corgi registered by the way, just wanted a few extra ideas. let you know how i get on.
  3. C

    No hot water

    Hi. I have a saunier duval semia f24e condensing boiler. The problem is i have recently noticed that the hot water was running cool. The boiler/burner flame lights, stays on for about 5 seconds and cuts off and fires up again for 5 secs. It does this in heating mode too. I have checked the...
  4. C

    Is this normal?

    Have you got a tap stat (similar to a thermostatic rad valve) fitted on the pipe coming out of the hot water cylinder. the bathroom rad is probably a bypass for the hot water. The boiler problem sounds like a thermost problem. Is the pump working properly and do the downstairs rads get hot.
  5. C

    radiator wont get hot

    it means that you need to turn your upstairs rads back on 1/2 a turn each until they are working and get warm again. kitchen rad should stay on.
  6. C

    My Baxi 80 eco combi Boiler - no hot water coming from taps

    Not sure if they have a flow sensor? Sounds like the rubber diaphragm in the diverter valve has perished. Not expensive to replace. have you had the case off? Check if the pin moves freely on diverter valve.
  7. C

    radiator wont get hot

    when you bleed it does it heat up then? try and turn off all other rads and see if it heats up. System could need balancing - Tuning all rads to work together. If that don't work you could replace the rad valves. Hope this works.
  8. C

    boiler flue distance

    how many kilo watt kw is the boiler? look here, good diagram and chart. http://support.ambirad.co.uk/Article.aspx?id=10724
  9. C

    saunia duval f24e flame fault?

    Hi. I have a saunier duval semia f24e condensing boiler. The problem is i have recently noticed that the hot water was running cool. The boiler lights, stays on for about 5 seconds and cuts off and fires up again for 5 secs. It does this in heating mode too. please help!!
Back