Search results

  1. F

    HW but no CH but it's not the 3way valve?

    Try moving the mzv manually,or take the head off and see if the spindle will move,it should move easy
  2. F

    Towel rail or radiator?

    If it's cold,dont go for a towel rail,you need a rad,im sick of telling customers " go for a rad,a towel rail wont heat the room up".Im told to fit a towel rail,then a cold spell comes and a call "the bathroom isnt hot enough,can you sort it out",so i end up having to fit a rad,but they still...
  3. F

    Central Heating - Flushing or Cleaning

    Why ? not get a bit of hosepipe,push it as best you can over thee ball valve and into the cold feed,if you cant do that then try and get mains pressure into the cold feed,it will force any air out and refill the system.I was sick of trying to fill systems back up,so i made a connection that...
  4. F

    Heating system circulation problem

    Are you sure the system is full or its not pumping over,so when your venting is the h/tank filling up.I would first off get a valve to shut the h/w circs off,and then see how it is,if theres water in the system and its firing up,pump working then the heat iss obviuosly going somewere and if the...
  5. F

    Central heating circulation problems continue !!!!!

    Why not think about getting the system pressurised,just a vessel in place of the tank,its much better for a system that size which is getting proplems,with auto air vents fitted,air will find its own way out,i would put some internal leak sealer in as well,it sounds like your losing water somewere
  6. F

    24i worcster fires up but ignition carrys on and it cuts out

    Macca i apologise,i checked it just for curiosity and couldnt believe it when the neutral lit up and the live wasnt.I had work done only on the lights and that was 6 weeks ago,ive swapped them over and its working,shall i get a spark in or get him back and find out if he has done something and...
  7. F

    24i worcster fires up but ignition carrys on and it cuts out

    Thanks nickso,i will check it out. I dont think macca's advice is going to suceed,but cheers anyway. Im going to have a look now and make sure im not overlooking something.
  8. F

    24i worcster fires up but ignition carrys on and it cuts out

    Ive got a 24i worcster boiler,it fires up but cuts off after 10 sec,and the sparking still carrys on after it fires up any ideas please lads
  9. F

    Glow Worm Space Saver 40 MK II - Boiler Problems

    It shouldnt take a person who knows what he's doing long to tell you thee exact fault,after he's checked t/c and o/h stat,and has done the obvious things eg cleaned pilot and got a nice size pilot,then he would say gas valve but its easy to check t/c and o/h stat but are you sure he done that
  10. F

    Advice On Refilling System To Avoid Air Locks

    I dont mess about anymore i get some hose pipe connect onto the main in the loft and push it into the cold feed in the h/tank and it fills no proplem,any air pushes out with ease
  11. F

    worcester 28i rsf combi no ignition

    Could be air pressure switch,try blowing very lightly down tube
  12. F

    worcester 24cdi diverter valve

    I would make sure you have everything you need before trying it , a washer kit incasee you need to remove heat ex.I hate them i now do them in situ as i took one out in 20 min and took me 4 hrs to get it back without any drips so now its just a diapraghm i change ,the only awkward screws are top...
Back
Top