  1. A

    rommsealed AR issues

    hello id lik some of your thoughts. been reading hse reports for past ten years and seems roomsealed boilers are involved on average in one death per year( out of 25 million homes ,probably only about 5mill of those are checked every year)how often are you seeing leakages? ar or id roomsealed...
  2. A

    boiler in loft

    hi. ive been asked to do agas check. boiler is in loft. combi. does it need fire protection? boxed in? or something. im asking because the lady bought the flat 2 years and was told it needs fire protection?? ive never heard of this. i assume if it requires but doesmnt have then its ncs...
  3. A

    landlords gas check legal requirements

    could someone clarify tightness test on landlords cert not legal requirement ( surely not) co test not legal requirement? thanks confused!!
  4. A

    call out illegal?

    hi. i work for a gas firm doing social housing contracts. it employs 200 people. i work 8-5.30 mon to fri. however i have signed no emplyement contract nor have i signed the e.u. opt out working time directive. im expected to do call out mon-fri after work and all sat and sun every fifth week...
  5. A

    filling condensate traps

    hi guys. i was at a job with one of the guys fromm our firm doing service. ecotc 824. i noticed the trap wasnt hughely full so i poured some water down the flue to fill it ( prevent possible flue gases from escaping). anyway this chap said hed never seen that done before ( 5 years experience)...
  6. A

    overheating

    on a open vent'heat only boiler if the boiler flow temp is considerably higher then the return and boiler overheats then this can only be dry system, pump knackered,airlocks?? what would be the symthoms of airlocks in central heat system ? overheating preceded by loud noises in pipework?ta
  7. A

    scaled plate exchangers

    could anyone tell me what would be the result of scaled plate exchanger? poor dhw flow, poor h/w temp as there would be karge temp differntial on flow and return? anything else? wouldnt the boiler overheat if the plate was scaled up?thank you
  8. A

    thermocouple

    on permamnet pilot boiler ie puma 80p, if the pilot was staying lit but main burner was not lighting you could rule out defective thermocouple as a cause since the pilot is staying lit thus the thermocouple must ne ok. am i right? i know its basic but just past my acs after years in army...
  9. A

    pump overun

    past acs . was easier then i thought. can i ask one thing. i understand how pump overun works on combi. however on a s or y plan with a boiler wired for pump overun how does the pump know when to stop running since there's no stat? does the pcb have some kind of clock timed for 5 mins to run...
  10. A

    permissible drop

    acs put back till friday. two lads from my regiment said it was fine but just curious about one thing. no smell of gas 4mb drop is permissiable with cooker connected but not permissiable on pipework. whether a 4 mb drop is on pipe work or connected appliance. cant see how one is acceptable and...
  11. A

    gas fire

    thats for previous spillage help. if acs chap asks about poor burner pressure at gas fire the cause can only be gas meter regulator fault, incorrect pipe size and incorrect gas rate would be injector kanckered. thats all i can come up with as an answer . what do you think?
  12. A

    radiant fire spillage

    thanks for previous input on acs preperation . one on spillage . scenario is radiant fire ie firegem. flue test goes perfectly. assuming no fan present, spigot is not blocked and sufficient space behind spigot for poc exit what else would cause it to spill. its past the flow test perfectly so...
  13. A

    acs

    doing my acs next week so revising hard. just would like some pointer. i understand they simulate gas leak so i want to be 100 percent on method of tracing it, permissiable drops etc. i have a g4 meter, boiler and gas cooker connected. u gauge reads 4 mb drop over 2 mins. do the following--...