Search results

  1. J

    Plastic Panels

    hello all, Pulled a load of tiles off today in a bathroom and need to install these panels. Last walls i did them on were sound, these ones are all over the show, short of replastering, any tips on how best to go about it...? PS, i gotta start this tomoz so any advice soon as would be...
  2. J

    Appears to be no earth

    hello, Just been to look at a rewire, electrics are so old its unreal, thats not the question though... The supply side is very new and updated, its a TNCS earthing system, but there is no earth coming out of the neutral from the supply, in fact no earth in sight whatsoever, anybody know why...
  3. J

    3 flats rewired

    Guys A house needs converting into 3 seperate one bedroom flats on 3 floors, each with its own supply. Is this more than likely to need a 3phase supply?
  4. J

    Earthing System

    Was on a job today where the meter side of things has been upgraded, but the customers side of the installation was dire... On the supply side it looked like a TNS with bracket and 2 nuts, but this was going up to a block like TNCS with no earth coming out of the neutral at all, any ideas?
  5. J

    What Drill?

    Im looking for a cordless sds hammer drill, and also a diamond core drill for extractor fans, anybody know of a drill that would do both jobs? _____________________________________ Lynda, moderator, moved as posted in WRONG FORUM
  6. J

    fireproof boards

    can anybody point me to a link were i can get a fireproof board to mount a consumer unit on, please?
  7. J

    DNO Query

    I have a rewire to do next week. The electricity board have condemned the property and pulled the fuse, before doing that though they have upgraded their side of the installation. I have not made any enquiries as yet to this, so im asking a few things before being pre informed. 1) Do i...
  8. J

    June 2391 Results

    Anybody heard any news? When are the results out? Whats the expected pass rate? Anything?
  9. J

    125 mA mystery box

    Hello all, By my mother in laws fusebox there is a small box with 125mA fuse written on it, 2 telecom type wires come out of it, got no idea what it is, anybody? its about the size of a ciggie packet
  10. J

    What power?

    Need to wire this shower up tomorrow, all the instructions state is connect it to a 13amp socket, no wattage anywere in book, anybody any ideas? http://www.showerforce.com/ntpages/sfn1500XT PS, i know its only going to be a 3amp fused spare, but nevertheless i still want to know what power...
  11. J

    Cat D

    fellas, I am interested in buying this car advertised, it is advertised as Cat D, i did not know what that meant, the lady told me it was in an accident about 5 years ago.. Can anybody tell me if this is a problem with the car, as it is advertised for a bit less than it should be...
  12. J

    March 2391 paper scenario

    fellas, I know nobody has the march paper at hand, but does anybody know, or who has taken the test what the scenario is on the 2nd part??
  13. J

    Quick r1+r2 question

    Just a quick question Why do we have to divide the end figure by 4?
  14. J

    IR Test

    On insulation resistance testing i have noticed most of my various books i have make reference to just testing the insulation as a whole, how would you transfer this over to the schedules though? as they have specific boxes for each individual circuits value?
  15. J

    PIR Practice

    Well i have just finished doing a PIR of my house, its only 5 years old so circuits are in good nick. I did most of the circuits by the book and i pretty much got the figures that were anticipated. Just a few of questions before i go downstairs and crack a bottle or 8 open. 1) All you...
  16. J

    Different Values

    In the OSG and the brown Amicus book there is different values regarding max Zs. Example, rating 32amp in OSG its 1.2, in Amicus 1.5, another example, rating 6amp, in OSG its 8, in Amicus its 6.4 ???anybody
  17. J

    Short circuit info

    Hello all, a bs 1361 fuse 100amps has a short circuit capacity of? and were is this info available please? I know mcbs are 6ka and rewirables are between 1ka and 4ka
  18. J

    Quick Question

    A normal healthy ring circuit, if i do an insulation resistance measurement on this circuit what figures am i likely to come up with? PS i am familiar with minimum figures in table 10.1 of OSG
  19. J

    DVD RECORDING DIGITAL FREEVIEW

    Hello All, My dad has just bought a dvd recorder to go with his digital freeviw tv. Problem is i cant seem to tune it into the digital part oif the tv, the analogue side tuned no problem, any ideas??? PS i forgot to mention, the freeview digital is built into the tv
  20. J

    Clipsal

    Anybody know who deals with clipsal products? Rang, newey & eyre, cef, denmans, nobody does them
Back