Changing Thermostat????

Joined
26 Feb 2007
Messages
48
Reaction score
1
Location
Cumbria
Country
United Kingdom
My 20+ year old current Sunvic TLX room stat has 3 wires going to it (plus earth) and has been tested as follows:
#1 Yellow - Switched 240v
#2 Not Used
#3 Red - 240v
#4 Blue - Neutral

I have an unused Danfoss RMT230 room stat (wiring diagram below) and wonder if it be a compatible replacement for the old Sunvic TLX I currently have?

Would it be a direct swap, using the colours mentioned above (yellow, red and blue) in the positions/numbers shown below on the Danfoss RMT230?

RMT230.png
 
Sponsored Links
The RMT230 is designed to, as the name suggests switch 230V. (Your diagram shows 24v)

Capture.JPG



So in your case, the RMT230 would connect as follows:

Live (red) goes to 1 'COM'
Switched live (yellow) goes to 2 'ON'
Neutral (Blue) goes to 'N'
 
The RMT230 is designed to, as the name suggests switch 230V. (Your diagram shows 24v)

Duh! Of course it is! How did I not even notice that?

I wouldn't, care but I was sure I pulled that image from a PDF downloaded from the Danfoss site after searching for "RMT230", so don't know how I ended up with that particular diagram. Weird!

So in your case, the RMT230 would connect as follows:

Live (red) goes to 1 'COM'
Switched live (yellow) goes to 2 'ON'
Neutral (Blue) goes to 'N'


Thanks for that info Stem, it is much appreciated, but still cannot believe I never even noticed the "24v" at the bottom of that image. LOL
 
Sponsored Links

DIYnot Local

Staff member

If you need to find a tradesperson to get your job done, please try our local search below, or if you are doing it yourself you can find suppliers local to you.

Select the supplier or trade you require, enter your location to begin your search.


Are you a trade or supplier? You can create your listing free at DIYnot Local

 
Back