Recent content by Ab12

  1. Ab12

    Magnetic door contact EOL? Help

    Thanks will try in the morning. Ah okay the two silver terminals are connected to each other in the contact already, how does the 4k resistor work if they're already connected without the resistor inplace?
  2. Ab12

    Magnetic door contact EOL? Help

    Although the drawing you did has confused me. The contact has gold, silver, gold, then silver, gold. So not sure if I just follow the positions or the colours as the silvers seem to be connected together
  3. Ab12

    Magnetic door contact EOL? Help

    Thanks both, sorry forgot to mention in an EOL setup. Seems bigsosij has posted what looks like EOL wiring?
  4. Ab12

    Magnetic door contact EOL? Help

    I am trying to wire a magnetic door contact with the pyronix euro V10 system. I have these...
  5. Ab12

    How do I isolate my boiler - combi

    Hi all, Need to change the pump head in my Worcester Bosch combi boiler. Is there a way for me to isolate and drain only my boiler to swap out the pump? - if so could anyone assist. Or do I need to drain down the whole system?.. Boiler is Worcester greenstar 35cdi Thanks...
  6. Ab12

    Next issue with my Worcester Bosch and Hive

    Established it might be the pump sticking. Freed but it stuck back up again. Is it a simple job of changing pump head or does the whole assembly need to come out. Question is really, does the pump head have the pump impeller on it or does that remain in the boiler and may still stick
  7. Ab12

    Next issue with my Worcester Bosch and Hive

    Ok a few of you will know my last few posts of swapping out a 3 port valve for 2 X 2 ports, and wiring in hive for CH and stats for UFH. All controls fine, valves open, boiler fires... and so becomes my next problem The boiler, set at 5 on the HW dial, gets a call for heat. Heats up, gets to...
  8. Ab12

    Strange Worcester Bosch issue (built in timer)

    Looks like it's not working again.. argh
  9. Ab12

    Strange Worcester Bosch issue (built in timer)

    Just coming back to my initial question. Not that it hugely matters. But still seems odd to me. The manual for the programmer simply shows a plug and play installation, which would mean to me it's an unplug and go un-installation, so.. still very strange to me that the Lr at 240v from the hive...
  10. Ab12

    Strange Worcester Bosch issue (built in timer)

    I have a combi boiler with a radiator zone and UFH zone correct! And thanks for the well wishes on getting it working. Glad I have! I ended up getting the 3 port zone valve out and getting 2 dual ports in. First one is my UFH, it's controlled by the UFH wiring centre, which is controlled by...
  11. Ab12

    Strange Worcester Bosch issue (built in timer)

    Thanks, so it seems to be a, leave it installed and set to permanently on for heating, and if used for HW also to permanently on. Makes sense, thanks!
  12. Ab12

    Strange Worcester Bosch issue (built in timer)

    Hi guys, after a bit of help... Have just wired up my system with a hive and UFH setup with zone valves. All working great thanks to help from everyone here. The problem I have found is that the system will only fire (when for example hive calls for heat), if the built in timer is plugged into...
  13. Ab12

    UFH and CH S plan

    Anyone? Going to get to look at this in the morning..
  14. Ab12

    UFH and CH S plan

    Got this all working now and have a few final questions. Balancing out the CH this weekend. I have salus auto balancing valves for the UFH, so can't see a need to balance the UFH itself. But... Do I need to balance the UFH against the CH in some way to make sure their flows are "equal and...
  15. Ab12

    UFH and CH S plan

    So in theory the wired hive could replace the salus', but would need batteries to be changed often as the only con. Agree wireless would be very busy!
Back
Top