Recent content by aptsys

  1. aptsys

    Kitchen counter LEDS are faulty- uniformly dim

    It's nothing to do with that anyway. The shift in spectrum is the tell-tale sign
  2. aptsys

    Are Downlight Covers Required With Led Units?

    what's the random switch back there?
  3. aptsys

    Kitchen counter LEDS are faulty- uniformly dim

    If the photo shows the true colour of the LED (yellowy slightly green light output), then the phosphor has degraded. Pretty common at that age and will need replacement.
  4. aptsys

    How to connect and wire Oven and hob (Ed.)

    A photo of the connections at the oven terminals are likely to reveal the issue.
  5. aptsys

    Opinions on kitchen downlight positions

    I don't understand this? Normally no one uses the main room lighting after installing task lighting and extractor lights :cautious:
  6. aptsys

    Vortice Lineo 100T - running extremely slow

    Replace the capacitor. Mine did the same a few years ago
  7. aptsys

    Hager Bluetooth AFDDs

    All modern RCBOs have some electronics too, I guess it's something no one has ever thought to mention before.
  8. aptsys

    Hager Bluetooth AFDDs

    Saw this pop up yesterday, thought it was interesting. Actually not too badly priced from wholesalers, though the Hager website shows double the price.
  9. aptsys

    Generator to supply domestic boiler

    The fans on modern boilers are quite powerful, at full load often over 100W.
  10. aptsys

    Extractor fan advice - do humidistat fans work well?

    The major cost is heat loss, likely to cost hundreds of pounds in the winter for the extracted air which must be reheated to maintain internal temperatures. Better to install an MHVR system if you want continuous ventilation
  11. aptsys

    I damaged my meter tails

    Double insulated isn't the same as insulated and sheathed cable ;) I doubt the supplier will do anything about it. You might have more luck with the DNO.
  12. aptsys

    Repairing a cut Virgin Media broadband cable

    Normally Virgin use a different cable up to the isolator, triple screened and much larger in diameter. Just call Virgin out for a repair.
  13. aptsys

    Huge condensation in the bathroom, what to look..? Any tips..?

    They're dumping 480 litres of heated water per shower, I don't think cost is an issue!
  14. aptsys

    recessed LED strip lighting in bathroom

    Firstly don't use "IP65", tape. The resin discolours over time, but also affects the colour temperature of the LEDs and reduces thermal dissipation. Secondly, use a good quality tape or you'll find the LEDs failing. I often run them at a lower voltage to increase the lifetime, since the headline...
  15. aptsys

    Solar Panels with Batterys

    Originally somewhere around 230 miles on average, now maybe 150 miles which gets me 2 days of travel.