18mm tiles.
It was a Norton clipper ceramic extreme turbo. £30 ish from tool station.they don't seem to do them individually any more??
But it was the green 1 in this pack.
https://www.toolstation.com/norton-clipper-diamond-blade-triple-pack/p76039
I laid a load in my back garden the other year. Sounds like you have most of it sorted.
For the primer I mixed the sbr with cement till nice and green and not tooo viscous. But it does stick like mad, so as u say clean the tops asap. Although I found with mine I could use wire wool to get off...
We got our kitchen from DIY-Kitchens and self fitted.
We got a Quartz worktop from DIY-kitchens as well.
IT was out sourced to, http://www.naturalstonesurfaces.co.uk/
Cant fault the guys at all. They came and did a lazer measure rather then a template.
Then a team of 3 came to fit and were...
Could you not change the build up?
Say 50mm celotex, then the warm up element. Then a 55-60mm screed then the tiles?
you only have screed to go off then rather then the concrete and insulation board adhesive before applying the tiles..
Note I am not qualified in any way but its what I would...
I have the beam in place now.
But I still need to get it packed up ready for inspection.
https://goo.gl/photos/QU4qB4reW1NMuvAy6
Cheers for your thoughts.
I am glad I am not the only one who ends up in this situation!
I did do a search, but not found too much relevant. But that is probably...
I'm trying to figure out if my se specified an less then ideal beam.
Basically i have a design based on 2 parallel flange channel beams back to back. They are rigidly but bolted together.
On the inside i can wedge some wood in the channel and cover with plaster board.
But what do i do on the...
This is true. But if it is a large distance from the boundary to the rails that will reduce the risk of affecting the operational railway.
I guess the main things they are worried about is affecting their foundations, making sure nothing will land on the line or could knock out the OHLE.
The words state, "within 10m of the operational railway"
I would take that to be within 10m of the closest running rail, not the land boundary.
How close is the nearest running rail to your boundary?
So it looks like it will be safe, as I guess it should be.
It just wont be as efficient a system as it could be with the boiler kicking in and staying on when its not 100% required.
Ahh well.
Cheers
I'm looking at installing the poly pipe overlay system in my 1994 property when i knock a couple of rooms together.
The boiler is a brand new ideal system boiler on an s plan with a non vented tank.
My understanding is that the there will be a new 2 port valve and thermostat to run the boiler...
Cheers for the info.
Yes I am aware of building control. I have someone looking into the beam calcs at the minute.
I am getting the window company to fit the bifold. Im quite happy to have a go at putting the steal in place with the help of my builder mate, but I dont fancy installing the...
We are planning to knock out a large hole in the back wall and install a 4.4m aluminium Bifold.
At the moment there is a patio door and window which will be replaced with one bifold.
See the Red lines on the pic below.