Recent content by Carl1973

  1. C

    External Garage / Workshop Electrics.

    I got my my TLA's muddled, but I didn't post on here to be ridiculed... Work will be done by a part P qualified electrician, I was just doing my homework! I'll just go elsewhere..
  2. C

    External Garage / Workshop Electrics.

    So I bite the bullet and channel out the concrete to run it sub-surface.... would it be practical to run it from a 45A RCD in the house to a Garage Consumer Unit in the Garage and out of that to a Garage Consumer Unit into Workshop.. What size / type of cable would be recommended.
  3. C

    External Garage / Workshop Electrics.

    Garage will be two strip lights and just a single double socket to be used for the odd powertool and possible welder... Workshop will be set up with similar lighting. and 3 double sockets for a table saw, chop saw, router etc.... The garage electrics would not really be in use whilst in...
  4. C

    External Garage / Workshop Electrics.

    I have to run a power cable from my house to garage, the distance is approximately 12 M. It would be a pain to bury the cable due to the distance also being concreted. I am aware that over that distance it should be 3.5m high and supported on a catenary wire but it is not practical due to the...
  5. C

    Soil Pipe from downstairs toilet

    It looks like I will be getting a professional in for this part of the job, can anyone give me an ballpark figure for installing a new soil pipe and getting it to run into the manhole if the current one is of no use. The manhole is about 2 metres from the rear of the property. From what I...
  6. C

    Soil Pipe from downstairs toilet

    OK fair one, however I do believe two questions can still be answered without speculation.. 1. Is it plausible the stack could just be a vent for the sewer. 2. Can you split an "in floor" soil pipe to take another These questions along with a thorough inspection which would reveal...
  7. C

    Soil Pipe from downstairs toilet

    Good morning all :wink: I have just have had an offer accepted on an epic DIY doer upper project. At the rear left of the property is a down stairs toilet that has the waste going directly into a floor waste pipe. On the exterior wall of the toilet is a soil vent pipe which the current...
  8. C

    Garage Wiring

    I concur, I have had a brief look and being a single skin single storey detatched garage it probably won't need planning permission or building regs, but the limit is set at 30 Sqaure metres for building regs not being required and it will run over slightly hence going through the pre-planning...
  9. C

    Garage Wiring

    In Lincoln just off the A46 Bypass
  10. C

    Garage Wiring

    I am about to submit a pre-lanning applcation to see if I need planning permission (£72) and then will take the advice given (if required) on any building regs etc.. prior to going the whole hog on the £150 planning application. Thanks for the other advice, will have to find myself a good...
  11. C

    Garage Footing

    Thanks, will check if there are any problems in my area etc..
  12. C

    Garage Footing

    Just being picky to be honest, my old garage is on a slab and I just prefere the thought of bricking up of the foundations and pouring the floor in level with a course of bricks..
  13. C

    Garage Wiring

    Singles it is then, just figure it will be easier to run through 20mm conduit, I intend to do the first fix myself running all the cables and then get a sparky in to connect the SWA to the fuse box in the house and the garage consumer unit etc so its all certified but saving a bit of labour...
  14. C

    Garage Footing

    Hi All, I am planning a new garage build. It will be single skin with single brick pillars at the appropriate intervals for re-enforcement. Thus making the wall 215mm wide. I figure a footing of 450mm Wide and 600mm deep, will this do the trick? Regards Carl
  15. C

    Garage Wiring

    Hi All, I am looking at building a new garage, compete with electrics etc. I am fully conversant with the 2.5mm Flat twin & earth for a ring main and 1.5mm Flat twin & Earth for lighting. Question.. Can you use 2.5mm & 1.5mm 3 core flex for the same wiring (IE: is it in line with...