Recent content by Craggy

  1. C

    Cosumer unit reccomendation request

    I'm not hoping i now have someone who is going to fit it. I have however taken away the risk of someone obtaining a sub optimal fit product by just popping to screwfix and getting the next best thing. And why would you think that? does a proactive approach to procurement not sit well with...
  2. C

    Cosumer unit reccomendation request

    Hello, thankyou so much for all of the replies, this has really helped understand what the requirements are and consider what i should buy. I've decided to purchase the item myself from TLC and will take the cost of the units out of the equation. i went for a flush 10way, with SPD, and have...
  3. C

    Cosumer unit reccomendation request

    Hi, I have just got a flat and think i want to have the consumer unit replaced, purely owing that it appears quite dated. the wiring was installed in 1987 ish, everything works fine. Is it good practice to replace this unit below?, and if so I wanted some advice on what consumer unit type I...
  4. C

    Pressure loss on unvented system with ideal logic boiler advice required

    hi. bit of an update, there are two pressure gauges on the system. one is upstairs besides the tank, the other is under the boiler literally attached to/part of the "flow" tap on the left underside of the boiler. this is the part of the test still whereby the flow and return to the boiler is...
  5. C

    Pressure loss on unvented system with ideal logic boiler advice required

    Hi, thankyou very much for the detailed response, this is very helpful and appreciated. this weekends job is to work through what you have suggested and I am currently patiently waiting during step 5d! (the flow and return were stiff and awkward bot seems like no leaks from them yet) can i just...
  6. C

    Pressure loss on unvented system with ideal logic boiler advice required

    hi thanks, could that explain the pressure loss in the system? as currently i keep being told that pipe has no effect on pressure, which is what i am doubting, or at least getting a 2nd opinion on
  7. C

    Pressure loss on unvented system with ideal logic boiler advice required

    ps, it is the gauge in the bottom left corner of the cupboard that loses pressure, the one near to the tundish is stable.
  8. C

    Pressure loss on unvented system with ideal logic boiler advice required

    hi thanks for the replies, hopefully the pictures help... it is the last picture that the pipe to the outside behind the tank absolutely pees out when boiler is on. i have noted that expasion pressure vessel and heat exchanger test may be things to try before searching any more for leaks. i...
  9. C

    Pressure loss on unvented system with ideal logic boiler advice required

    Hi, I am seeking help on what could be potential faults with my central heating/ hot water system. For over a month it has been losing full pressure after one use. i.e., re-pressurise to 1+ (1.5 bar when on), on long enough to get a tank of hot water and it loses all pressure in that duration...
  10. C

    opening up first floor chimney breast

    Hi, As part of an extension we had on our house (was 1930's 3 bed semi) the original back bedroom 2 was split in two, half for the bathroom and half for the front bedrrom 1 wardrobe. I would like to put fitted wardrobes along the inner wall but it is ruined by the fact that the chimney...
Back