Recent content by cwyn

  1. cwyn

    worcester 25Ri flashing blue light - clicking with Video

    Bought a nearly new PCB board off ebay for 20 quid and it's now sorted. Still got a plumber coming to give it a check over and service. Think I may have saved £245 :shock: Thanks for the replies :D
  2. cwyn

    worcester 25Ri flashing blue light - clicking with Video

    Hi anyone who may be able to help? ....I have an issue and routine with this boiler of it fails to initiate its timed programe I then reset it, all ok for a while, next time the progam is supposed to heat water andCH I get a blue flashing light (mostly off-flashes on, as the book says) then...
  3. cwyn

    WORCESTER CONDENSING BOILER IS THIS 'IGITION LOCKOUT' ??????

    Hi Nicetoseeyoutoseeyounice, (anyone else who may be able to help?) did you sort out the problem with the boiler? ....I have exactly the same issue and routine of reset, all ok for a while, next time blue flashing light (mostly off-flashes on, as the book says) then may stay on for...
  4. cwyn

    Window frame fixing

    What do you suggest the cill should sit on then?
  5. cwyn

    Window frame fixing

    "Windows look a mess when the cill is sat on a mortar bed" BUT it's the correct way to fit it.
  6. cwyn

    Water not draining under UPVC door

    ..looks like a brown water mark at the back of the cill, easiest way if the coat hanger did not clear is to run a 5mm drill bit "carefully" through the existing drainage holes making sure they exit the bottom frame...but NOT into the projection cill below it. Then get a cup of water and test again.
  7. cwyn

    Window frame fixing

    I would say your window needs to sit on a 15 to 20mm mortar bed with fixings up each jamb at least 160mm from each corner/weld. Do not screw through the head..either use a cleat and/or fixing foam.
  8. cwyn

    Condensation in double glazing

    noooooooooooooooooo , don't try the repair!! just replace the "sealed" unit.
  9. cwyn

    hot water pressure in kitchen bad/bathroom fine? what to do?

    because no one answered my first one :)
  10. cwyn

    anyone?

    It's same crap flow taps fitted or not.
  11. cwyn

    anyone?

    I have a hot water copper tank in my ground floor bungalow airing cupboard and a worcester greenstar boiler in the kitchen (not combi) The problem I have is since buying this place 2 years ago is the extremely slow running and low pressure from just the kitchen tap. Even without a tap fitted...
  12. cwyn

    hot water pressure in kitchen bad/bathroom fine? what to do?

    I have a hot water copper tank in my ground floor bungalow airing cupboard and a worcester greenstar boiler in the kitchen (not combi) The problem I have is since buying this place 2 years ago is the extremely slow running and low pressure from just the kitchen tap. Even without a tap fitted...
  13. cwyn

    Replacement/ fire regs / no one knows!

    it's number 17 here ...any ideas??? https://picasaweb.google.com/100355590217338121267/105_FUJI?authuser=0&authkey=Gv1sRgCOPL4ePl4ImSVQ&feat=directlink Cheers
  14. cwyn

    Replacement/ fire regs / no one knows!

    woody you say...The only requirement under the b/regs is that the windows do not make the situation any worse. Thats the problem.. the design has to stay as the existing and as the new ones are PVC then by design they will make it worse? Many other companies have copied the existing designs...
Back