Recent content by dagger

  1. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    @ianmcd please can you give me final pointer so I can proceed - much appreciated
  2. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    lol - the VR65 is not the box in my original picture, it is the Vaillant wiring centre which is mounted on the wall near my boiler. The VR65 is a completely different small box and is just what the householder uses to turn the heating up et. I thought I had it clear in my head earlier but now Im...
  3. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    I will, but Im still a little bit confused as to whether I should be removing this wiring centre box completely and using the Hive box instead based on Ians instructions or whether I'm keeping this box in situ and running a few cables from my hive box TO this - I only say this as Ian says leave...
  4. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    ohhh, so Ive just realised you're saying leave this wiring centre box in place and run a few cables from it to my Hive box. I always assumed we were removing this wiring centre box altogether and replacing with the new Hive box
  5. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    ok so Ian, final question I promise :-) when you say I can 'just leave the wires' going to the cylinder stat, do you mean i just sheath them off safely and not connect them to anything at the Hive (& not to each other either) and just leave the other end of them connected as they are at the stat...
  6. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    oh god I hope not - what do you reckon Ian ???
  7. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    yes the white cable is the cylinder stat cable
  8. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    ah brilliant - many thanks just out of interest, if I did just remove the cylinder stat wires altogether would it still work but just keep heating the hot water with no temperature limit?
  9. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    Many thanks Ian, can I just clarify what you mean when you say 'interrupt' with the 2 wires going to cylinder stat?
  10. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    yes I do have a VR65 (its crap) but its all going (hopefully) to be replaced by Hive So my two questions are; 1/ with Hive can I just safely sheath off the Bus wires currently running from the boiler and not connect them anywhere on Hive?? 2/ the two cylinder stat wires - where do I connect...
  11. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    by the way black cable goes to MA1 3 port valve
  12. dagger

    Plumber said my Vaillant wiring was beyond him & he couldnt install my Hive ????

    I bought a 2 channel hive and asked him to install, he took the cover off the wiring centre and saw this and then said it was beyond him and left - anyway, I want to do it myself and wondered if anyone can confirm what I do with the two wires going to Bus sockets (as its a vaillant Ecotec 837...
  13. dagger

    paint to touch up brick

    ok thanks
  14. dagger

    paint to touch up brick

    Hi everyone, is there such a thing as a small size touch up paint for me to paint a dozen bricks or so as they have had old screws and such like taken out and then mortared over (badly :-) by me so they stand out as the mortar is much paler than the surrounding browny red bricks. Ive found a few...
  15. dagger

    quick question about installing a vertical radiator please

    ok thanks, not worried about the 'looking a dog' bit as itll be permanently behind a chest of drawers on one side so invisible
Back