    1926 kitchen and bathroom refurb

    Looking for advice on how to finish kitchen and bathroom walls on an old non-cavity wall. I have done A LOT of research into this and to be honest it has now become overwhelming. There never seems to be an agreed method and I really dont want to make the mistake of picking the wrong method and...
  2. D

    Float and set or dot and dab?

    How did you get on
  3. D

    Lighting help

    Ok I can see his point, in that case I would probably say 80% of the houses in the UK are dangerous :roll: . We have always used JB's in lofts and under floorboards, but would never bury one in a wall. And as usual the wiring regulations are vague on what is and what isn't accessible. Where...
  4. D

    Lighting help

    What's the problem?
  5. D

    Raised decking over steep slope project/advice

    I'll start by showing some pics of the proposed site - I've never known what to do with the area, it's quite large so could become a handy sitting space to look out over the garden. I'm an electrician by trade but really want to do this project by myself (with a bit of help). I...
  6. D

    Lighting help

    Daisy chain your downlights from the ceiling rose to whatever locations you want, make a detailed joist/cable plan AND DON'T LOSE IT :lol: Change the ceiling rose to a JB, you can use a pattress and blank plate with connector blocks if it's easier. You will need to connect the first loop of...
  7. D

    Wickes ceiling light, push fit electrical connection.

    Can you upload a pic? With push fit to release the cable you normally have to press a small tab, make sure that it isn't pressed down. If you are trying to connect flex into it then that can sometimes be difficult, twist the end nice and tight before you try and get it into the push...
  8. D

    Downlight Install

    More than likely separate switch wires but could also have used a 3 core, why not unscrew the ceiling rose and have a look?
  9. D

    Ventilation in porch - condensation

    Anyone? I have same problem, or would a 4 inch core hole and grill be an alternative?
  10. D

    Plug socket branching off from a lighting circuit

    The problem with this is someone can come along and plug something with a higher load into the socket. My advice would be take 1.5mm t&e from the pendant to a fused spur, install a 6A fuse, then from that to a standard 13A double or single socket outlet. Or you could cut the plug off the...
  11. D

    Florescent light causes ceiling fan/light to flicker.

    If there are 2 separate circuits you could try splitting them up by adding another MCB to the consumer unit. My knowledge is a little rusty but someone correct me if I'm wrong here - The fluorescent uses a capacitor/starter and this works by creating a voltage spike, as voltage increases the...
  12. D

    Bathroom extractor not so FANtastic???

    Hi Mandy, what type of extractor fan is it? ie make and model. I presume it is low voltage? you can then find out the volume of air it extracts and compare it to other fans, it may just be a weak fan? You'll find in winter more steam is generated, colder temperature = more steam. As long...