    Seating area with Raised Pond & Planter

    Hi, The wife wants a L shaped seating area with a raised pond & planter as backrest. All concrete rendered. (Damm you Pintrest!) I've been doing some research & have been advised to use a single skin of 9" (215mm) or 6" (140mm) wide hollow blocks with rebar then filled in with concrete. It's...
  2. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    Hi all, Finally found someone for a reasonable price ;) Cheers all for the advice.
  3. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    Hi, Thanks all for your advice. I'm based in Hungerford, West Berkshire (RG17) so a bit far from London to connect a hose ;) Anyone around here want to connect a hose? Thanks
  4. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    ahhh... I was told Micropoint only came in 3/8" bore & that 1/2" only came in the old style fatter connector with 4 little holes in the end & would need a new socket on the wall, thus more work cost... Any idea who sells a 1/2" bore Micropoint Gas hose? <edit> I think I found it...
  5. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    Hi all, The plonker was doing some kitchen work for me & need to get behind the cooker. Needless to say he's not a Gas Safe Plumber otherwise I'd be saying reconnect it! Yeah, I'm getting the feeling £330 is a bit of a I don't want the job, but I'll make it worth my while sort of quote...
  6. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    Hi, Thanks for the reply guys. I needed the cooker reconnected after some kitchen work, as the guy who moved it unscrewed the hose as well as disconnecting the bayonet! I'd like to make sure if the 1/2" upgrade is actually needed considering it's been fine for the past 8 years & it's...
  7. D

    3/8" or 1/2" Gas Hose for a Dual fuel cooker?

    Hi, I've had a 4 Gas Safe registered engineers give me a quote to reconnect a Hotpoint EG51G Dual Fuel Cooker, although they seem to be split on whether I need to upgrade from a 3/8" Micropoint to 1/2" Standard to provide more gas? It only has 4 burners & a grill operating on gas as...
  8. D

    Can I replace a dead Pumped Shower yourself?

    Hi, That's seems to be what most people have said, although he just wanted to check the Legal situation as he has a tenant in the property with the shower? Thanks
  9. D

    Can I replace a dead Pumped Shower yourself?

    Hi, Can an existing pumped shower be replaced (like for like) by a normal person or do you need a qualified plumber &/or electrician? From what I've been told it has 4 screws, Hot & Cold push fit connections for feeds & 240v for the pump. Note: It is an pumped shower on the wall of...
  10. D

    Can I replace a Single Rad with 2 series?

    Hi, Currently doing the bathroom & looking to replace a single radiator (600x700mm) with 2 x 500mm wide Towel Radiators. I've also match them up for their heat output. They will be right next to each other literally a few cm apart, so I thought we could connect them in serial...
  11. D

    Double checking if this a load bearing wall?

    Hi, The joist definitely sits on top of the wall, no gap. I'm not sure what trimmer joists are can you give me a quick explanation of what I should look for? There a pieces of wood @ 50x30mm hung in between the joists. They sit perpendicular to the joists on small metal hangers...
  12. D

    Double checking if this a load bearing wall?

    Hi, The joist actually sits on top of the wall. Along the top, the entire length. Upstairs 1/2 a dividing wall between 2 bedrooms carries thru to the joist/wall downstairs. The rooms are rectangular with the corner taken out for the other room, so the this section of the dividing...
  13. D

    Double checking if this a load bearing wall?

    Hi Guys, I just want to double check if a wall is load bearing. I have a wall between the Kitchen & Dinning room which spans 3.8m I've drilled a few exploratory holes in the plasterboard ceiling & wall to find the floor joists for the bedroom upstairs. They are the new engineered...
  14. D

    Armadilo Outdoor Cable Kits, Regs & Part P

    Hi, I'm installing pond pump & lights in the garden & was considering using an Armadillo pre-assembled kit as it apparently is meets Regs & Part-P. With the "Permenant Wired" kit with the junction box on the end, you obviously have to wire in your pump & lights. But how far can you go...