Thank you. I will set keypad link to #1. Cant find a setting for the number of keypads so will just have to try it. I will have to try to tell it there is not a telephone modem, then link the line monitor to 12v
I dont know how much of that I can program as I only have the User Code.
Is there...
Hi Sparky, I have a Gardtec 800 and like some advice please. Mine was working when I moved in but I relocated main unit, RKP and PIRs. I remember having to cut the siren lead to silence it.
I now need to recommission it. Got a new battery, what is the procedure?
Also had 2 control panels. Only...
Gasguru
Can you help
Hot water cycles very hot to very cold at intervals of about every 10 seconds
Any ideas of how to fix or what I can test?
Could it be another diaphram operating a switch like the one I replaced before?
Heating still seems to work on its own
( although I can hear a...
Hi Gasguru
You are right, of course,
looked more carefully
the heating does come on when not commanded
But now got worse
Hot water cycles very hot to very cold at intervals of about every 10 seconds
Heating still seems to work on its own
Diverter valve? or something that signals it...
Gasguru
Thanks for reply
Thought that sounded like a lot of gas
Gas flow seems to be same whether or not DHW is at correct temperature
No, heating comes on at correct time, was just commenting that the temp of the radiators always seems to be very hot and doesn't go luke warm like the DHW...
Gasguru,
I read the meter and with the water running at the tap but not as hot as it should and be flow rate was 2580 cu m per hour.
The radiators always seem to get very hot
Thanks once again
Regards
Mark
( the heating pressure seems to have settled down now to a stead 1bar cold 1.5...
Gasguru,
Prob 1
DHW gets only luke warm from any tap about half the time
turning on and off sometimes cures it.
Not sure, but don't think it ever gets to max temp when tap is turned on full.
Flow seems to be a bit jerky.
Prob 2
Not noticed pressure getting towards 3
Keep pumping it up to...
Hi Gas Guru
Thanks for previous help
Now got more problems
replaced diaphram and cover as recommendeAll ok for a while
Thanks again
Now DHW doesn't always get very hot
Seems to be loosing pressure - I keep topping it up - cant see a leak
Any help very much apreciated as always
Mark
Thanks guys :D
I had the same problem ie DHW staying on and sometimes over-heating
Sometimes not coming on when demanded
Just looked and the pin is sticking
Will buy some WD40 tomorrow
Or is there something better?