Recent content by fine tune

  1. F

    Gouge in gas pipe before meter. Ignore?

    nothing to worry about , just some marks from stiltsons when they first fitted pipe .
  2. F

    What are the best adhesive-sealants?

    the best and one of the cheapest https://www.toolstation.com/multi-stick-grab-adhesive-solvent-free/p38941
  3. F

    Bungalow has extension or conservatory? How to find out?

    tony if you put the name of the district council planning in google, go to view or comment in the planning applications website ,it take you to the simple search section put the address in it will show any applications as far back as it goes .
  4. F

    How to reduce shower spray

    set shower to reqd pressure stick it in a empty bucket for a minute, measure how many litres you,ve got and order the nearest flow reducer
  5. F

    One pipe central heating system

    top of page ,comes under faqs
  6. F

    Rusty hot water but the cylinder is copper. Any ideas?

    galvanised feed tank in loft/airing cupboard feeding hot water tank rusty inside
  7. F

    7/8 (approx 30 mm) connector on a 3/4 outside water tap

    https://www.amazon.co.uk/d/9q9/Draper-Expert-68430-4-Inch-Garden-Hose-Connector/B0001KA0FE/ref=pd_lpo_vtph_86_bs_lp_tr_t_1?_encoding=UTF8&psc=1&refRID=QVHCQWT526DGDDXVXXJ4
  8. F

    Water Hammer

    most likely to be neighbours stoptap where plumber turned off water , stoptap could have a loose washer/jumper , if its only just cracked open the jumper will bang against the seating , go round and turn it fully on and noise should stop
  9. F

    Torbeck valve problem

    The noise is caused by the water coming out of the four holes in the end cap ok thought you where talking of a sgeal when shutting off , properly be able to seal it, bit of a weak spot had them do it when new .
  10. F

    Torbeck valve problem

    theres a little flap that acts as a guide, its slipped out of place , if you prize end cap off you can put it back , should be trapped in place with cap. it will not stop the noise though. pm add ill send a new one
  11. F

    worcester 28si II

    seem to to think these anti seize come on every once every 24hr, and can be set to come on at a more reasonable time say 4pm or what ever, by turning power to boiler off then back on at isolation switch at 4pm or what ever and it will come on every 24hr from then .cheers
  12. F

    worcester 28 si c/h ok no h/w

    you can discount the diverter valve , this boiler hasn,t got one,
  13. F

    Mira advance atl thermostatic update

    maybe caused by kinked hose , blocked head, if stats got 240v to it but not out needs a new stat , not resettable, cheers
  14. F

    Mira advance atl thermostatic update

    check overheat stat has not tripped on top of element