    Doubtful. AI assistant answer: Prosecutions Publicly reported court cases specifically for solely unauthorised removal of the cut-out fuse (without additional elements like meter tampering, bypassing for theft, or harassment) appear rare or not widely documented in mainstream sources, court...
  2. flameport

    Can an electrician swap my MCBs for RCBOs?

    If you want a single specific item in BS7671 that states 'do not connect solar to multiple circuits' then no, there isn't. If that type of thinking was continued, BS7671 would be thousands of pages of specific entries attempting to cover every situation possible. Fortunately standards are not...
  3. flameport

    Can an electrician swap my MCBs for RCBOs?

    Bidirectional devices is 530.3.201 which was added in Amendment 3 of BS7671 18th edition. For PV not connected to RCDs which supply multiple circuits, in BS7671 this is mainly covered under disconnection times 411.3.2.1 where if the PV inverter is connected to multiple circuits, when the RCD...
  4. flameport

    Can an electrician swap my MCBs for RCBOs?

    But if trouble had occurred, they might have preferred something more recent with additional safety features. Like driving a 40+ year old car with no seatbelts, no airbags, no antilock brakes and a mixture of cross ply and radial tyres. All perfectly fine and safe until it isn't.
  5. flameport

    Can an electrician swap my MCBs for RCBOs?

    A novelty item of little benefit in most situations. Problems being stored up for the future.
  6. flameport

    I wish people would label things 40 years ago

    Fluorescent tubes are obsolete. Production and importation ended over 2 years ago. All that's left now is old stock that certain vendors have hoarded to sell at high prices.
  7. flameport

    Can an electrician swap my MCBs for RCBOs?

    It will, because most of the cost is the items inside the consumer unit, the installation of them and the testing of the circuits connected. The actual box on the wall is an insignificant part of the total. All solar PV requires that, and solar cannot be on an RCD shared with other circuits...
  8. flameport

    Double Socket Warm to Touch

    It's a brand which only Screwfix sell. Whether it's good or not really depends on what was specified for it and who made it. Built in USB outlets in general are a terrible idea as they are powered 24/7 including when not in use, so failure is inevitable. Those which some people rushed to fit...
  9. flameport

    how much do you think this building would cost to put right?

    £100k at least. Very easily a lot more. Fiction. That's exactly what it is. The building is at the edge of a tiny village in the back end of nowhere, right next to a primary school. Even if it was reopened as a venue, expect complains about noise, disruption and antisocial behaviour. It...
  10. flameport

    Indirect unvented cylinder with 15 litre flow?

    No, and it wouldn't be of any use even if there were. For multiple showers or other outlets in use at the same time, the flow is shared between them, so high flow rates are needed. That applies regardless of how the water is heated - if the flow into the property is poor, then it doesn't...
  11. flameport

    Very interesting video

    Legacy manufacturers turned out a selection of EVs which were total crap and overpriced. Unsurprisingly they didn't sell well. Those manufacturers which have recognised the error will be making better EVs in future. Ford possibly. Others such as Stellantis who believe that a big swerve back...
  12. flameport

    Alternator Repair

    Do not go there. Before anything else, check all of the connections to the alternator and the battery and the ground lead(s) to the vehicle chassis. Then if the alternator is indeed bust, buy a new alternator and a new battery to go with it. Even if you could replace the regulator, that may...
  13. flameport

    Do I have a gravity system or pumped & is it C/S plan?

    This is the hot water valve: The other black box with the rotary knob is the thermostat. Yes, but the wiring to the other items will also need to be checked/replaced. There are wires in the terminals that would be expected, those being the L&N supply and the two switched outputs to heating...
  14. flameport

    Do I have a gravity system or pumped & is it C/S plan?

    That was a normal S plan, which is all pumped. It's also reasonably modern, so forget about gravity/C plan/other, as that's all irrelevant and obsolete. Two 2-port valves, one located towards the front of the hot water cylinder, and the heating one has been removed, disconnected from the wiring...
  15. flameport

    Business monitor - no speakers or audio jack

    HDMI or Displayport audio extractor in the cable the connects to the monitor. random example: https://www.amazon.co.uk/Extractor-Converter-Splitter-Lossless-Soundbar/dp/B076T7Y4BJ