Refurbished PCB fitted this afternoon, everything appears to be good. Ran heating for 90 mins and no return of fault, as yet (fingers crossed). Stat buttons seem to be a bit stiffer than before, but you can still turn them freely enough. Thanks to all
Just ordered refurbished PCB from eBay. Is this something that I could do myself ( how easy and where is PCB located?) or would you say better to get engineer back?
Thanks for all your help so far it's greatly appreciated. Trust us to own a boiler with a unique problem. Spent a bit of money on boiler in past month, might be time to cut our losses, if fault cannot be resolved was hoping to fix, as money is tight.
No hot water originally and diverter was leaking water from casing not diaphragm that was replaced. Pump was replaced as not working correctly (low pressure). Basically boiler shuts down when central heating on for an hour, all lights turn off and boiler attempts to ignite but fails. I turn off...
I have a baxi 105e, it has been looked at by an engineer and has recently had new diverter and pump replaced. The boiler now has a problem with shutting down after CH has been on for about an hour. No problems with DHW just appears to be when CH is on. No error lights flashing. Boiler just shuts...