Recent content by galdaran

  1. G

    Baxi Duo Tec - E133 fault - Engineer Appointment booked

    I had a similer problem with my duotec 28he about 2 years ago. error code 133 and failing to light. the Boiler service guy said it was the igniting electodes had moved out of place and just needed to be straitened out, which he did as part of my service. :)
  2. G

    Boiler making a squealing noise

    Hi I have a Baxi Duo-tec 28He Combi boiler and it has started to make a high pitched noise which can be heard throughout the house. I have made a video of this noise I usually only happens in the morning when the heating comes on, rarely in the afternoon. Normally I end up turning the...
  3. G

    Baxi Duotec squeeking

    I have a baxi Duotec he28 and had a few radiators replaced a few months ago. The plumber drained the system to change them and when testing them after refilling the system he was outside with the heating on and the boiler started to make a noise as if it were boiling dry. I Rushed to the...
  4. G

    Condensate drainage in winter

    Just looked this up. Its a soak away hes put in tho not sure about the distance he put it from the house but guess i gotta trust him lol. anyhow, with the last 2 bad winters never had a problem with the condensate freezing in the down pipe. Maybe this would be a better soloution for...
  5. G

    Condensate drainage in winter

    Not a plumber or even a decent DIY sort of person but when i had my boiler replaced the new boiler was placed where the old hot water tank was due to no space where the previous boiler was situated. The Condensate tube for this is just ran straight down the outside wall (with a bit of...
  6. G

    Bulldog 1st gen TRV settings

    Anyone able to help with what teperatures are at what setting for a 1st gen Bulldog TRV since my installer didnt leave any info for them settings are 0 * 1 2 3 4 5 i know 0 is off and * is a frost setting but i dont know what temperatres these equate to
  7. G

    wireless Thermostat placement

    Thermostat is a CM921, boiler is a baxi Duo-tech He28.
  8. G

    wireless Thermostat placement

    When i had my boiler changed and TRV put on the radidators the plumber who did the work left the radidator by the front door (bottom of the stairs) as the one without a TRV, and mounted the thermostat at the bottom of the stairs. However this is only a small area though is subject to...
  9. G

    Which Boiler to choose

    For the Vaillant ecotec pro its 2130, to upgrade to the plus would cost even more, tho i havent asked how much. Where as this quote for the baxi or potterton is coming in at 1900 and has the bonus that it can be done next week and i know someone that the plumber has done work for before so...
  10. G

    Which Boiler to choose

    ok i have chose a plumber but hes offered me a choice of boiler Baxi eco-tec pro 28 or potterton promac 28. I thought these were both the same but looking at which the potterton got a lower mark. Which do you think is best or are they both the same?
  11. G

    Which Boiler to choose

    Hello. I'm looking to upgrade my old appollo 15/30b boiler to a new one. I have 2 quotes so far but i am unsure about them. I have a 3 bed semi detached house, with 9 radiatiors. one quote for £2136 is for a vaillant ecotec pro condensing combi boiler (will this be sufficent for my...