Recent content by gasman1987

  1. G

    Rough install ??

    i know as I was there on the first fix . As the gas engineer ( I hold all electrical qualification also but only for surveying) I am anal when installing but it's evident when workmanship is lacking . Left exposed cables when stripping out with just the Mcb turned off and I was making them safe...
  2. G

    Rough install ??

    I think so , best of all it's a council contractor working for council in a private house , The shower keeps tripping out and unable to get the contractor back out so sent my sparky and he said its rough, said it should have a new board or at best facing where it's been cut for Mcb I need...
  3. G

    Rough install ??

    Hi all, Visually the install looks rough but to name few problems I don't no how it's been signed off The house was rewired 3 years ago and all is ok with this work but a extension has been completed and several new circuits upgraded onto the existing board * incorrect manufacture breakers on...
  4. G

    Worcester 28i greenstar. Possible pcb

    Hello, No instructions on site but am thinking it will be pcb but need some ohms reading to test as can't find any online I have a constant flashing light on the display. Cheers
  5. G

    Earth in wires

    I thought that this didn't comply with regs. I would say a lot of the older properties never do but from a maintenance point of view I always install a double insulated product but there is nothing protecting the cable.
  6. G

    Earth in wires

    I'm a heating engineer and if I was to wire the 10 way box and controls components I would always want to run a cable with the appropriate amount of cores including a earth, I always come across wires where they use the earth as a live wire . Can this be done Most of the controls are double...
  7. G

    City and guilds 2330

    I am looking at going collage to finish my electrical course , I already have 2330 level 2 but don't no what course I should be looking at now as there are so many to choose from and the numbers mean nothing to me Please advice
  8. G

    Halstead ace / no hot water

    Just a quick question regarding the diverter assembly on a halstead ace, as it has pressure sensing pipes, The pin does not activate the micro switch . would usually just replace the diverter to eliminate call backs but could there be a alternative reason on this model why the pin does not...
  9. G

    pendant in bathroom

    it is a normal pendant in zone 2
  10. G

    pendant in bathroom

    please can someone confirm if you can install a pendant in a bathroom.
  11. G

    LPG in a camper van

    thats fine, i will get a cp12 from this other company.
  12. G

    LPG in a camper van

    well the conversion company says they don't have to issue a certificate but they can get someone out to check it for a extra charge. i find it strange as you don't have to in a domestic property get it checked after a installation and u get a building certificate. just wanted it clarifying if i...
  13. G

    LPG in a camper van

    Don't the company that fitted the appliances have to provide a installation certificate like a house . i am thinking why would they say this is a extra charge, i suspect this company was not gas safe. which i would consider a illegal installation i no that each year i would need a new cp12...
  14. G

    LPG in a camper van

    Oh sorry forgot you can get a LPG covertion for the engine. My post relates to the two gas cookers that are inbuilt into the kitchen Cheers
  15. G

    LPG in a camper van

    I have had my van converted by a professional company. My insurance required a gas certificate, should the company that fitted it supplied the certificate. As they are saying this is a extra cost of £110 by another person. I suspect the conversion company are not gas safe and this is why the...