I'll try to get shower details later
wasn't too much muck in old CWS tank, but maybe some,
will check filters on any taps
Could you attach a mains fed hose to the gravity cold water outlet somewhere and backflush? possible to cut into pipework in loft and fit valves to allow "backflush"...
Thanks, its only got 1 outlet as have all these local ex council houses, the CWS & F&E tanks overflow into the gutters (I've changed that in lads house)
I'll re-check how shower is fed,
Trapped Air = as this one pipe feeds Hot water cylinder and the cold water taps/toilet ect, (other than...
yes Water level the same and outlet bore the same
only differance is outlet is 50mm higher on side of tank, (before it was under the tank)
so my thoughts are its just. before all the waters wieght was pushing down on/in outlet, now it just sidewards pushing (and of course lost 50mm of water...
Hi folks, just replaced an old cold water storage tank and replaced it like for like
except the origanal one had the feed outlet under the tank and now the outlet is on the side, the pressure now at the hot taps & the electric shower is noticely lower than before, is it simplely that the weight...
sorry about the delay in getting back
no photos of setup yet
hot water pipe comes out top of the tank *right angle then on to Tee connector" other ends of Tee 1 is the vent pipe up to the cold water tank, the other drops tp floor level feed to all hot water outlets
there is no separate pipe...
Hi guys, I can get the air out by connecting washing hose pipe to hot pipe and run cold water though the hot pipe
But its happening every 3-4 weeks (been like it for 20 yrs or more) so want to try to stop it
Live it a dormer bunglow, Cold water tank in roof, hot water cylinder on first floor...
would that hold up to the weather ?
i get a lot of wind and rain that side of house
just had a re-measure area is 147cm x 136 cm
so would need a joint in the renderboard
if i put up strips of marine ply, should i put insulation boards to fill the gap ?
should i screw or glue the renderboard on...
hi all
got a small concrete block wall that needs re-rendering (old render looks like it was removed years ago) it between 2 windows its only around 1.5 sq mts (1.3 mts X 1.25mts)
it needs 30mm to bring it out level with the brick work either side of the windows
here is my thoughts/plan
1...
Do I get an air separator or a combined deaerator and dirt remover ?
I was looking at the Spirovent 28mm, but spiro don’t do a combined 28mm unit
I don’t want the plastic bottle unit
Whenever I drain/refil the system I always get air trapped, it takes ages for it to clear
And now I’ve...
sorry got the terms the wrong way round,
thought flow was feed into the boiler
and return was the hot water coming out
so the flow coming out of the boiler (Hot) has a vent on it
and the return (cooler) goes into the boiler
so its still the same question just the terms I used need to be...