Recent content by heathelect

  1. H

    Outdoor security Light

    was the original light a security light with a sensor attached, was there a switch inside to switch it on and off as well ?
  2. H

    Wiring under ground to front boundary

    We always use a conduit mouse, I keep mine in a matchbox in my top pocket !!!
  3. H

    Automatic cars.

    big automatics are brilliant easy to drive, should have them more over here, i wish my boss would buy me an automatic van.
  4. H

    Removing bedroom pull cord switch - old wiring

    Yes thats right and so are all the other proposals
  5. H

    Removing bedroom pull cord switch - old wiring

    Nice one mate, didnt think of that one
  6. H

    Removing bedroom pull cord switch - old wiring

    1)Remove single and earth red from between pullcord and light. 2)remove twin and earth cable from pullcord and re-route to light connect the red only back into the light. 3)At the wall switch disconnect the black of the twin and earth. 4)If switch operates upside down connect red of the...
  7. H

    Armour termination

    holmslaw. Why are you questioning sunrays competence, with these derogatory remarks, people like you are of no help to others, and i find it offensive to read this rubbish.
  8. H

    As a sparky would you certify work done in your own house.

    Well said Rf !!!!!!!!!!!!!!!!!!!!!!!!!
  9. H

    Concrete gutters leaking - how to fix?

    I have these concrete gutters on my bungalow, over the last 30 years ive tried all sorts to seal them. The solution is to line them with lead. Job done no more leaks, they have been done for 6 yrs now well worth the cost of buying the lead on a roll and doing yourself, but remember safety...
  10. H

    As a sparky would you certify work done in your own house.

    Yes I meant notification, Dave
  11. H

    As a sparky would you certify work done in your own house.

    Yes bas I can, as I said its a hyperthetical question !!!
  12. H

    As a sparky would you certify work done in your own house.

    Yep ok,as I thought. But its only a hyperthetical question !!!!!!!
  13. H

    As a sparky would you certify work done in your own house.

    Hyperthetical question. I am 52, been in the electrical trade all my life. Was self employed for 20yrs until recently and was NICEIC registered. Got all the appropriate qualifications, I now work for a local electrical contracting company cards in. Question is-: Would you as an...
  14. H

    2, two way pullcord switch wiring

    Beat me to it (but i would normally put the brown of the 3c into the common terminals of each pullswitch) doesnt matter which way round you connect black or grey into L1 & L2