    missing Actuator valve

    I`ll get mine.. missed the part when he said they were capped off... :oops: Been reading it fer yonks scratching me head. Penny just dropped.
  2. J

    10mm OK to feed a shower?

    And : For the record nobody but cowboys,diyer`s would ever dream of piping up any supply in less than 15mm pipe and never in plastic or pushfit fittings. :wink:
  3. J

    Should I put additional blocks under the bath legs

    Fair point,the only time I add timber or support to a bath is to gain height. Each to their own experience,not criticizing any views. :wink:
  4. J

    Flush cistern problem

    Overflowing into pan,so floatvalve not shutting off or overflow height needs adjusting, ,simples.
  5. J

    baxi duotec mk2

    Sounds like thermistor or flow switch problem. Do you know were they are? Have a look in your manual.
  6. J

    Flush cistern problem

    Your bog has an internal overflow, controlled by a floatvalve, either your floatvalve,(much same as a ballcock) has failed or requires adjustment.
  7. J

    10mm OK to feed a shower?

    Pressure does not differ,circumference/ length of pipe run affects both flow, delivery and temperature. Contradiction.
  8. J

    Radiators not heating up. - New System

    How many rads in total? was system working before adding rads?. Boiler can`t cope with extra distance to new rads. How big is the frikkin house?it`s a combi fer chrissakes , designed for small houses and flats! It`s a glorified water heater, I hate them with passion. I have a back...
  9. J

    Should I put additional blocks under the bath legs

    Been fitting baths for the last 15 years on chipboard/floorboards,never known any leak to cause any major problems. :wink:
  10. J

    Radiator/heating question

    Last time I visited Arizona,they had air conditioning.
  11. J

    Cracked external drain - need fixing?

    Hopper head relates to higher level drainage. External drainage is not trapped. Bullsh#t More bullsh@t yeeawwn.
  12. J

    Boiler switch of problems

    Not sure about your boiler but sometimes after you turn off the boiler the pump continues for a little while to get rid of all the heat, so when you turn boiler off,it`s sounds like it is still running for a while. :D
  13. J

    10mm OK to feed a shower?

    10mm to your basin? must take a week to wash your face.
  14. J

    Radiators not heating up. - New System

    Size of boiler?, length of pipe run?, how many stories? where is boiler situated? :?: Advice please..