Recent content by James Osborn

  1. J

    Texecom 48 Impaq Plus Wiring

    Changed zones to EOL wiring and now working as expected. Thanks for your assistance.
  2. J

    Texecom 48 Impaq Plus Wiring

    Thanks Sparky, we have progress. I am now getting a resistance change when the magnet is moved away from the contact, however like the shock sensor, it's is not placing the zone in an active status, instead it is staying secure?
  3. J

    Texecom 48 Impaq Plus Wiring

    Excuse my simple mind on this sparky, but do I link both tamper terminals on the panel zone 3 to a global tamper on the panel?
  4. J

    Texecom 48 Impaq Plus Wiring

    Hi sparky, Thanks for the quick reply. Tried removing brown from both door sensor and panel but zone status is still active ?? If the wiring looks good i may try removing from the door and wiring direct to the panel. I did check the brown and orange cable and am getting continuity though... strange.
  5. J

    Texecom 48 Impaq Plus Wiring

    Sorry for the delay coming back to you. Pictures attached.
  6. J

    Texecom 48 Impaq Plus Wiring

    Guys, help I am struggling a little wiring an Impaq Plus with magnetic contact to a Texecom 48 panel. I am getting a resistance change on the shock zone1, however its not going to an active state only staying as secure, and I am not getting anything from the contact zone2, its stuck in an active...
Back