    Artex and asbestos

    Hi -I live in 1960's house and renovating my kitchen. I started removing the artex covering on the cieling and have since found that it could contain asbestos. I have removed about 3 sq meters at the moment and have another 10 to do. Should I continue or stop and seal it in and board...
  2. J

    Shower switch went bang

    Thanks guys. Would it make sense that the shower has gone through 2 switches in a couple of days?
  3. J

    Shower switch went bang

    Hi - does anyone have any idea on the following ? I was renovating the bathroom and when doing so got an electric shower to put in an electric shower. An electrician installed the shower on 10mm wire, 40a rcbo, 45a switch and the shower is 9.5 kw. I have the work fully certified. The shower...
  4. J

    Cable size

    Thanks - realise it is done that way. I have used a spark before when I did my extension. He gave my a wiring diagram and specified the material etc to be used. I am going to use this spark again, but would like to do some research on the circuit first so I can ensure his design is ok.
  5. J

    Cable size

    Hi Guys, I am installing an electric shower. I am going to lay the cable and then get a spark to sign-off and do final connections. I am just ordering the materials and after some guidence on the cable size from someone who had access to a copy to the 17th edition. Shower: 10.5KW...
  6. J

    Noisy shower thermostatic mixer

    Hi - Have just converted my garage into a bathroom. I fitted the following shower: http://www.screwfix.com/p/triton-tesla-thermostatic-mixer-shower-flexible-exposed-chrome/36111 The shower makes a buzzing/screaming at certain temparature points. It is connected to low pressure hot...
  7. J

    Plug sockets

    Thanks - I think i might be digging them out of the wall - fun!!!!
  8. J

    Plug sockets

    Hi - I live in a 1960's house and I am justupgrading the plug sockets. The cable is still good (its PVC in black an red). The issue I face is that the original plug sockets and back boxes have the screw holes and the top and bottom - does anyone know of a modern socket that has screw holes at...
  9. J

    noisy check valve

    I have the valve in the correct way, I understood that the mixing takes places within the tap, in a modern tap, and that creates the risk of cold flowing up the hot. I guess I could fit a PRV to the cold and then take out the check valve?
  10. J

    Pressure equalising valve

    Hi guys - Has anyone used a PEV before to balance a thermostatic shower (hot is ravity fed - 0.7 bar, and cold is main - 3 bar). Are they noisy? Do you need check valves with them or is this built in? Apreciate advice. Cheers
  11. J

    noisy check valve

    Ok thanks. I read somwhere about taking out the spring - have you done that before?
  12. J

    noisy check valve

    Thanks Tony - so step one - I shall try another check valve. Unfortanely the whole house has unbalnced supplies as the cold is direct to every outlet.
  13. J

    noisy check valve

    Hi - I have just installed a mixer tap. The hot is feed by low pressure gravity system (head of 6m) and the cold from mains. Despite the pressure differences the tap works fine. However I was concerned about the cold running up the hot pipe so I fitted a single check valve. The issus is that...
  14. J

    unbalanced tap feeds

    does it make a diffrence if the mixer is lever controlled Vs indepnednt hot and cold controls?
  15. J

    unbalanced tap feeds

    Hi Guys - I am just trying to resolve an issue with my bathroom. I have bought a basin and vanity unit with a single tap hole and therfore need to get a mixer tap. The hot is low pressure (has 6m of head) and the cold off the mains (3bar). I initialy bought a a lever mixer tap. I have not...