Recent content by jc86

  1. J

    Duravit Soft Close Toilet Seat - adjustable?

    Hi! Wondering if anyone has any experience with Duravit soft close seats, and if they are adjustable? I have just fitted two, and they close very slowly to begin with, then gather pace and make quite a bang as they close. Wondering if they can be adjusted at the hinge somewhere...
  2. J

    Loud tìcking waste

    So......managed to get access under the bath. The spare inlet boss was touching an upright stud, so have trimmed that back which has helped stop the reverberating. However, where the waste inlet from the other room joins the vertical stack inbetween the studs, the pipe is expanding and...
  3. J

    Wunda w82rf stats

    Hi! We have a 4 wunda zoned RF thermostats, they seem to be locked into manual mode and we can't get them into programmable mode....anyone got any experience with these? Thanks
  4. J

    Loud tìcking waste

    As an aside, house is only 3 years old....surprised the SVP isn't wrapped in wool or fibreglass?
  5. J

    Loud tìcking waste

    That might be my next step...its tiles but looks like a screw rather than adhesive for access....
  6. J

    Loud tìcking waste

    Hi all After some advice.... We are getting fed up with our waste knocking each time we use hot water. the knoking seems to only when we run the hot water from a cold start in the ensuite. Guess the pipe is just cold and the hot water makes it move enough to make noise. I can feel the...
  7. J

    Safe Route and Lintel

    Yep perfect thanks for the helpful reply, that was my interpretation.
  8. J

    Safe Route and Lintel

    Hi All Looking for any advice if possible please. I am adding a couple of wall lights from the lighting circuit to my new garden room. I want to run a cable that traverses the proposed bifold doors underneath the lintel, so, two lights from one switched live switch, standard stuff. Is it...
  9. J

    Cold Rad, Not Stuck TRV!

    Hi, thanks for your reply. I have pushed the "nipple" up and down and run some grease into it, so i dont think its stuck. Wonder if its a balancing issue, but it isnt the furthest rad from the boiler and there is plenty of heat at the piping around the foot of the TRV (and the rad tail).
  10. J

    Cold Rad, Not Stuck TRV!

    Morning All, Got a frustrating issue with a cold rad. Its had its TRV turned down over summer and most of winter as it is in the spare room. Went to turn it up today, and its not happy. It isnt the furthest from the boiler, and all others in the house are nice and toasty. Its a new combi...
  11. J

    Reccomend me a shower!

    Hi! We are about to get our ensuite installed, but wondering about which shower to go for. Our old plumber said to get an electric one, but having had one before, I dont really fancy one. We have a 40kw baxi platinum combi. Currently got on thermostatic mixer in the family bathroom, which...
  12. J

    basin wastes and stud wall

    Thanks guys - appreciated
  13. J

    basin wastes and stud wall

    Thanks! That's good - just hoping there were no regs etc saying it wasn't allowed. The other question is that I guess we will need some batton in the stud wall to take the basin weight?
  14. J

    basin wastes and stud wall

    Hi! Looking for some advice. We are planning our bathroom, partitioning off a stud wall in our bedroom for an Ensuite. Ideally we would like a semi ped on one of the new walls. hot and cold csn come under the floorboards and up the stud wall with no problem, but can someone let me know...
  15. J

    Water Based Underfloor Heating

    Morning All, After any advice. We are putting a kitchen extension on our house, and we want some form of heating under the tiles. Its approx a 14m2 area. So, rather than using a large amount of electric underfloor heating, which will probaby amount to a couple of kw, we wondered about...
Back